background image

R

S

4

8

5

TA

M

P

R

E

LA

Y

1

R

E

LA

Y

2

TAMP2

TAMP1

12V/24V
AC/DC

PB1

PB2

GND

NO1

NC1

COM1

P

O

W

ER

P

U

SH

B

U

T

TO

N

S

G

R

E

EN

LE

D

NC2

NO2

COM2

A
B

GND

R

E

D

L

E

D

3

WIRING/ CÂBLAGE/ COLLEGAMENTO ELETTRICO/ CABLEADO/ VERDRAHTUNG/ BEDRADING   

+ -

DC Power

Supply

Diode 

ex. 1N4001

V+

V-

+

-

+

-

Diode 

ex. 1N4001

PB

GND

NO

NC

R

S

4

8

5

TA

M

P

R

E

LA

Y

1

R

E

LA

Y

2

TAMP2

TAMP1

12V/24V
AC/DC

PB1

PB2

GND

NO1

NC1

COM1

P

O

W

ER

P

U

SH

B

U

T

TO

N

S

G

R

E

EN

LE

D

NC2

NO2

COM2

A
B

GND

R

E

D

L

E

D

AC Power

Supply

V+

V-

NC

~ ~

~

~

~
~

NO

     C = 470 nF 

       R = 10K / ½W

     C = 470 nF 

       R = 10K / ½W

C
R

C

R

PB

GND

Electro Magnetic Lock

(AC powered)

Electric Door Strike

(AC powered)

Exit Button

(NO, mechanical or relay dry contact)

Electro Magnetic Lock

(DC powered)

Electric Door Strike

(DC powered)

Exit Button

(NO, mechanical or relay dry contact)

12 - 24 VDC(CC)  

12 - 24 VAC(CA)  

LED

+

12 - 24 V AC/DC (CA/CC)

-

VOLTAGE FREE LEDS/ LED SANS TENSION/ LED PRIVI DI TENSIONE/ 
LED LIBRES DE TENSIÓN/ POTENTIALFREIE LEDS/ SPANNINGSLOZE LEDS

~
~

to alarm system

to alarm system

Summary of Contents for EX6P

Page 1: ...RB0408 I O Codice PIN Scheda Codice PIN o e Scheda EM 4002 4100 e HID 125kHz fino a 5 cm 1 8 Cifre 2 2 verde e rosso 12 24 VAC DC max 150 mA S dalle impostazioni del menu S S per collegare schede I O...

Page 2: ...A 103B 103G 1 2 3 4 30mm 6 0 Cable 5 6 7 3 4 x 30mm CSK RB0408 Additional 8 relay board RU2 Additional 2 relay board DINRTT Push button and additional 2 relay board RTT Push button and additional 1 re...

Page 3: ...ER PUSH BUTTONS GREEN LED NC2 NO2 COM2 A B GND RED LED AC Power Supply V V NC NO C 470 nF R 10K W C 470 nF R 10K W C R C R PB GND Electro Magnetic Lock AC powered Electric Door Strike AC powered Exit...

Page 4: ...stanze maggiori utilizzare un cavo doppio intrecciato qualificato per RS485 Per utilizzare la scheda I O abilitarla dal menu EX6P Premere 000 B premere 5 1 A B per confermare Nota La scheda I O funzio...

Page 5: ...M2 A B GND RED LED 1 De jumper sluiten of dip schakelaar in RTT De eenheid piept continu en de rode led knippert 2 De jumper openen dip schakelaar 3 Wacht op een toon OK signaal korte korte lange toon...

Page 6: ...cken orange LED erlischt RS485 TAMP RELAY 1 RELAY 2 TAMP2 TAMP1 12V 24V AC DC PB1 PB2 GND NO1 NC1 COM1 POWER PUSH BUTTONS GREEN LED NC2 NO2 COM2 A B GND RED LED 1 3 1 De stroomtoevoer uitschakelen en...

Page 7: ...s 9 for Relay 9 OR AND Press 0 for Relay 10 Enter 000 Enter new Master code 1 to 8 digits Press from 01 to 99 for time in seconds If press 00 toggle mode Default 03 seconds Press from 01 to 99 for tim...

Page 8: ...Saisissez le nouveau code ma tre 1 8 chi res Appuyez sur de 01 99 pour a icher le temps en secondes Si vous appuyez sur 00 mode basculement d faut 03 secondes Appuyez sur de 01 99 pour a icher le temp...

Page 9: ...l rel 10 Immettere 000 Immettere un nuovo codice Master da 1 a 8 cifre Premere da 01 a 99 per il tempo in secondi Se si preme 00 si alterna la modalit Prede inito 03 secondi Premere da 01 a 99 per il...

Page 10: ...vo de 1 a 8 d gitos Pulse de 01 a 99 para el tiempo en segundos Si pulsa 00 se activa el modo de conmutaci n Predeterminad o 03 segundos Pulse de 01 a 99 para el tiempo en segundos o pulse 00 para el...

Page 11: ...s 10 000 eingeben Neuen Mastercode eingeben 1 bis 8 Zi ern Eingabe zwischen 01 und 99 f r die Zeit in Sekunden Eingabe 00 f r Schaltmodus Voreinstellung 03 Sekunden Eingabe zwischen 01 und 99 f r die...

Page 12: ...relais 2 instellen Uitgang toewijzen Timer I O paneel instellen Slave apparaat Zoemer Achtergrondverlichting Leesbereik Kaarttype selecteren Alle gebruikers verwijderen Een gebruiker verwijderen Time...

Reviews: