background image

 

WARRANTY 

 

XPOWER 1 Year Limited Warranty covers the unit from defects in materials and craftsmanship. The Warranty 
covers normal use for a term of one year from the original date of purchase including parts, labor and one way 
shipping.  
 
Warranty does not cover signs of misuse including, but not limited to, a unit that has been dropped, subjected 
to water damage, tampered with, improper voltage use and unauthorized maintenance and repairs.  
The POWER CORD and FILTERS are not covered by the warranty. 
 
Service 
 
In order to receive service or replacement parts under warranty, you must: 

 

Call XPOWER Customer Service at 855-855-8868 or 626-285-3301 for a Return Merchandise 
Authorization (RMA) number and return instructions. 

 

Have original proof of purchase. 

 

Use original packaging or Industrial certified packaging method. 

 
The end user will be responsible to ship the unit (with the RMA number showing on the shipping label) to the 
XPOWER Service Department. Upon inspection, we will advise you of the repairs needed and the cost (if 
applicable). XPOWER will provide repair or replacement parts depending on warranty. 
 
This warranty applies only while this appliance is used in the United States.  
 
 
 

WARRANTY REGISTRATION

 

Please  complete and mail or fax for your product warranty.  F or a multiple units, please list serial numbers on a separate sheet of 

paper.  Address:  XPOWER MANUFACTURE,  INC. 220 Clary Avenue San Gabriel, CA 91776, USA

 

Tel: (626) 285-3301;   Fax: (626) 285-3302

 

Company Name / Contact Person / Title

 

 

 

Address

 

City

 

State / Province

 

Zip

 

Country

 

Phone

 

Fax

 

E-mail

 

Model #

 

Serial #:

 

Date of Purchase

 

/

 

/

 

Purchased  From

 

Additional Comments / Suggestions

 

Summary of Contents for XD-125

Page 1: ...MANUFACTURE INC 220 Clary Ave San Gabriel CA 91776 PH 626 285 3301 FAX 626 285 3302 Email info xpower ws Website xpower ws COMMERCIAL DEHUMIDIFIER XD 125 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...of Contents INTRODUCTION 2 SAFETY INSTRUCTIONS 3 ASSEMBLY PARTS 4 SET UP OPERATION 5 CONTROLPANEL 6 CARE MAINTENANCE 7 Cleaning the Air Filter 7 Replacing the Battery 7 TROUBLESHOOTING 8 APDS I 9 WARRANTY 10 ...

Page 3: ...ign Semi Pneumatic Wheels Highly Durable Construction Model XD 125 SPECIFICATIONS XD 125 WATER REMOVAL CAPACITY 125 pints day 90 F 90 RH 76 pints day at AHAM 80 F 60 RH TYPE Standard Refrigerant R410A VOLTS HERTZ 115V 60Hz POWER 7 3 AMPS AIRFLOW 235 CFM OPERATING RANGE 33 100 F UNIT WEIGHT DIMENSIONS WxDxH 81 lbs 20 x 19 x 32 COMPRESSOR TYPE High Efficiency Rotary Compressor DRAIN HOSE LENGTH 20 f...

Page 4: ... not recommended or sold by the product distributor may cause injury to persons or damage to property 8 This product is intended for normal light commercial use only 9 Do not attempt to dismantle the appliance 10 Do not operate the appliance on a metal surface 11 Do not use the appliance in artificially hot or humid conditions or allow it to be used in any other hazardous environment 12 Do not cle...

Page 5: ...o ensure the best fit 1 Metal Handle 5 Air Outlet Grill 2 Control Panel 6 Air Inlet Grill 3 Semi Pneumatic Wheels 7 Power Cord 4 Water Hose Bracket 8 Water Hose DO NOT dispose of any packaging until you have confirmed the appliance is operational After removing the packaging ensure the contents are intact and complete In the unlikely event of missing parts contact your retailer DRAINAGE OPTION Whe...

Page 6: ...ater removal efficiency Keep traffic through drying area to a minimum Place the dehumidifier in the center of the room away from walls and furnishings Fig A Uncoil entire drainage hose on rear of unit Place open end of hose into a drain bucket or outdoors Ensure drainage hose is not restricted or kinked DO NOT elevate hose higher than 15 ft above unit Fig B Take care that water does not create a s...

Page 7: ...uminates to indicate when unit is purging either automatically or after selecting manual purge button Defrosting Flashing light indicates unit is defrosting Once defrost is complete the unit begins to dehumidify again automatically Running Light illuminates to confirm unit is plugged into an active power source Key Lock Function Press both T and P for 2 seconds at the same time Defrost light will ...

Page 8: ...in the diagram 3 Using a vacuum hose and nozzle vacuum any debris from the filter 4 Wash with warm water and a mild detergent and allow to air dry 5 Once the filter is fully dried re install 1 Confirm unit is turned OFF and plug is disconnected 2 Remove the screws in the four corners of the control panel 3 Once the screws are removed carefully lift the control panel to access the PCB 4 On the PCB ...

Page 9: ...t working time Allowmoreworking time Filterisblocked Cleanfilter Lowambienttemperature Increaseambienttemperature Condensation hose is blocked Checkhoseforrestrictions Dehumidifier is operating but roomis notdrying Doorsandwindowsareopen Seal roomfromexternal areas ERROR CODES CODE EI E2 E3 E4 ErrorMessage Coil sensor error Humidity sensor error Low or no refrigerant Water pump fault or blockage WAR...

Page 10: ...PDS I sold separately Uses combined power of XPOWER Air Scrubber X 3500 and Dehumidifier to remove moisture and contaminants from the air ASK125 Air System Adapter 8DH15 Ducting Hose X 3500 Air Scrubber ...

Page 11: ...ructions Have original proof of purchase Use original packaging or Industrial certified packaging method The end user will be responsible to ship the unit with the RMA number showing on the shipping label to the XPOWER Service Department Upon inspection we will advise you of the repairs needed and the cost if applicable XPOWER will provide repair or replacement parts depending on warranty This war...

Reviews: