Connections (for 2 or more Inverters up to 6)
Inverter functions:
1. Freezing damage prevention: This program enables continuous pump use, so as to prevent the water from freezing.
2. Automatic restart after stop: when there is no electrical power, or in any case where the pump stops functioning, the inverter stores the
last settings used while it was running and uses them again on restart.
If long periods of inactivity are required, remember to fully shut down the system.
3. High pressure alarm: when the operating pressure approaching the maximum pressure set, the alarm triggers. When the pressure
detected in the system drops below the maximum value, the alarm is cleared and the system resumes normal operation.
4. Low water level alarm: If the water level is too low, the inlet water automatically stops and the alarm is activated.
The system is monitored both by a sensor and an internal check.
5.Parallel operation: up to 6 pumps can run in parallel.
6. Dry running protection: automatically stops the system thus preventing damage.
7. Alternated start-up (for parallel operation): prevents the main pump from operating in parallel with multiple pumps.
8. Pump not running: when there are anomalies in the constant frequency of the electric pumps system, the alarm triggers, the faulty
pump is stopped and the nearest pump will automatically start.
9. Automatic check: When a single pump is running, the pump can be automatically started based on a specific time, so as to prevent
corrosion in case of long periods of inactivity.