specially developed for biological filtering, offers these bacteria ideal reproduction conditions. Inside the 
BIOCELL filter, toxic organic substances are transformed into natural plant food  – a natural process 
particularly contributing to the biological balance of your garden pond.

 

 
 

Assembly (Fig.

 

1)

 

 

 

Attach the spout connector

 

(5)

 to the fountain pump

 

(1)

 using the sleeve

 

(4).

 

 

Then attach the fountain tube

 

(6)

 by screwing it onto the spout connection

 

(5).

 The flange-and-

seal side must point upwards.

 

 

Finally, you can choose whether to attach the stepped fountain

 

(7),

 the bell-shaped fountain

 

(8)

 

or the bubbles-forming fountain

 

(9)

 to the fountain tube

 

(6).

 

 
 

Power connection

 

 

The device that you have purchased is already provided with a safety plug. The device is intended for 
connection to a safety socket with 230

 

V ~ 50

 

Hz. Make sure that the socket outlet is adequately fused 

(min. 6

 

A) and is in perfect working order. Insert the power plug into  the socket – the device is then 

immediately ready for use.

 

 
 

Commissioning

 

 

 

When commissioning the pump, obey the above security instructions.

 

 

Place the pump on a horizontal surface that is slightly above the pool/pond floor, which prevents 
the device from being excessively contaminated from the bottom sludge

 

 

Make sure that the inlets on the suction basket are not blocked.

 

 

Make sure that the pump is entirely covered with water. Do not operate the pump if it is outside 
the water or if it protrudes above the water surface.

 

 
 

Operation

 

 

The pump has 3 operation modes:

 

 

 

only as fountain (stepped fountain, bell-shaped fountain, or bubbles-forming fountain)

 

 

together with the spout connection to operate a water game

 

 

only with the spout connection to operate a water game

 

 

Operation with fountain only (see Fig.

 

2)

 

 

When placing the pump in the pond/pool, make sure that the fountain head protrudes above the water 
surface. If only using the fountain, you must close the stopcock

 

(A)

 of the spout connection by turning it 

a quarter turn clockwise. The stopcock

 

(B)

 must be open (see Fig.

 

2).

 

 

Operation of fountain and spout connection (see Fig.

 

2)

 

 

Mounting the pump is done as described above. You can connect additional water game with an inner 
tube diameter of 13

 

mm or 20

 

mm to the spout connection. The spout connection is opened by turning 

the stopcock

 

(A)

 counter-clockwise.

 

 

Operation with spout connection only (see Fig.

 

3)

 

 

Therefore, the stopcock

 

(B)

 must be turned 90°. The stopcock

 

(A)

 must be open. Thus, all the water 

flows through the spout connection, no water flows through the fountain.

 

 

 

Summary of Contents for 62547

Page 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...y avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbende...

Page 3: ...you for purchasing this quality product To minimise the risk of injury we urge that our clients take some basic safety precautions when using this device Please read the operation instruc tions carefully and make sure you have understood its content Keep these operation instructions safe ...

Page 4: ...such a device is available in the installation we recommend using a PRCD S intermediate switch personal protection intermediate switch To do this contact a qualified electrician This device is not suitable for use in swimming pools paddling pools of any kind or other water bodies with people s or animals being present during operation The device must not be operated while people or animals are in ...

Page 5: ...le min H05RN F can only be operated outside of build ings Pull the power plug before any maintenance work Should the pump cable or the plug be damaged the cable must not be repaired In that case the pump must not be operated any longer The pump can only be used for pumping water The pump must never be suspended from the pressure line or a live cable The pump must be protected from frost Children m...

Page 6: ...it is the user not the manufacturer who is liable for any damage or injuries Technical specifications Voltage V 220 240 Frequency 50 Power absorption W 50 Max flow rate ℓ h 1750 Max head m 1 6 with stepped fountain 1 1 with bubbles forming fountain 0 32 Max immersion depth m 3 Max bell forming fountain diameter m 0 45 Protection type IPX8 waterproof Max water temperature 35 Before commissioning Ma...

Page 7: ...s slightly above the pool pond floor which prevents the device from being excessively contaminated from the bottom sludge Make sure that the inlets on the suction basket are not blocked Make sure that the pump is entirely covered with water Do not operate the pump if it is outside the water or if it protrudes above the water surface Operation The pump has 3 operation modes only as fountain stepped...

Page 8: ...ntrol and maintain the pump In case the head or flow rate drops the filter must be cleaned with lukewarm water In case of hard water regularly clean the rotating parts of the pump Before prolonged periods of non use and before winter storage the pump must thoroughly be rinsed with water and completely emptied Allow the pump to be stored in a dry place In case of risk of frost the pump must entirel...

Page 9: ...eck voltage The device does not pump Blocked inlet sieve Clean inlet sieve with water jet Bent pressure tube Unbend The flow rate is insufficient Blocked inlet sieve Clean inlet sieve with water jet Reduced performance by heav ily contaminated water and abra sive components in the water Clean device replace wearing parts Caution The pump must not run dry ...

Page 10: ...separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment a...