Page 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...y avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbende...

Page 3: ...To ensure a good performance the compressor should stand in an aired clean and cool area Dusty or dirty air as well as high temperatures in the surrounding need to be avoided Make sure that the compressor is switched off before connecting it to the electricity After con necting it it can be switched on The voltage must not exceed or fall below the nominal voltage by more than 10 The air compressor...

Page 4: ...ressure switch please remove its cover and adjust the turning screw within Turn it clockwise to increase the air pressure and turn it counter clockwise to decrease it Note Always pull the plug to disconnect the compressor from the power supply before any kind of adjustments or repairs maintenance work is carried out Repairs and maintenance Any maintenance work must only be executed after the power...

Page 5: ...ec tor cuts the power frequently Voltage is too low Check the voltage must not be 10 lower than rated voltage Bad ventilation and high tempera ture Move the compressor to a ventilated area Air pressure is re duced when the ma chine is turned off Air pipe loose or leaking Check and fix it Water drain valve open Tighten the drain valve Check valve leakage Remove and clean it replace when neces sary ...

Page 6: ...https www XPOtool com Item 61017 Page 6 The Tool Experts 04 2022 1 Exploded view and parts list ...

Page 7: ... socket head cap screws M5 50 12 41 Observing hole 2 14 Connection pipe 2 42 O ring for observation hole 2 15 Connection pipe sealing circle 2 43 Drainage valve 1 16 Pan head screws with cross recess M4 6 2 44 Air tank 1 17 Limiting stopper 2 45 Washer holding screws 2 18 Air outlet valve clack 2 46 Big foot washer 2 19 Valve plate 2 47 Foot washer holding screw cap 2 20 Air intake valve clack 2 4...

Page 8: ...separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment a...