Item 50671–50673, 50675–50687

 

Page 4 

 

The Tool Experts

 

 

  

 

08 2022-1

 

 

It is not only used in the field of industrial heating technology but also in cooling and solar technology. 
Other fields of application

 

 

 

Combined Heat and Power

 

 

Air conditioning systems

 

 

Heating pumps

 

 

Floor heating

 

 

Thermal power station

 

 

Heat extraction

 

 

Air heating

 

 

Air conditioning in buildings

 

 

Food industry

 

 

Refrigeration and air-conditioning systems

 

 

Heating of domestic waters

 

 

Heating of supply networks

 

 

Solar thermal systems

 

 

Frost-endangered heating systems

 

 

Heating of regenerative fuels

 

 

Heat recovery systems

 

 

Vegetable oil conversion for cars and trucks

 

 

System division for underfloor heating

 

 

Chemical and pharmaceutical production process

 

 

Transfer stations in district heating supply network

 

 
 

Installation

 

 

Plate heat exchangers should be assembled in a way that there is sufficient space to perform mainte-
nance. The position for installation should be selected so that the plate heat exchanger can be ventilated 
and emptied. The minimum distance for the mounting on the thermal insulation is 40

 

mm. As for heat-

technical applications, a vertical mounting position is most effective. Any other position for installation 
could lead to power loss.

 

 

Refrigeration applications such as evaporator or condenser systems always require vertical installation.

 

 

Never assemble the heat exchanger with the connections in a downwards position. The heat exchanger 
should be preventively mounted on a console. A support only on the ports is not sufficient. Make sure 
that there are no vibrations and/or pulsations affecting the heat exchanger.

 

 

If necessary, you install expansion joints to ensure that there are no forces acting directly on the ports.

 

 
 

Connection to the pipe network

 

 

A – Primary side heating technology: primary in / out

 

B – Primary side refrigeration: refrigerant in / out

 

 

Heat exchangers are connected in reverse flow. The system needs to be rinsed before installing the 
heat exchanger.

 

 

 ATTENTION: 

Pipelines should be routed the way that movements inside the pipes or improper 

forces to not act on the plate heat exchanger!

 

 

 

Summary of Contents for 50671

Page 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insi...

Page 2: ...entirely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www...

Page 3: ...e heat exchangers It is the so called soldered plate heat exchangers that are preferred being characterized by the fact that the different plates are soldered with each other By this means you can ren...

Page 4: ...ted so that the plate heat exchanger can be ventilated and emptied The minimum distance for the mounting on the thermal insulation is 40 mm As for heat technical applications a vertical mounting posit...

Page 5: ...be ensured that there are no operating conditions being in contradiction to this assembly operation and maintenance manual The formation of ice causes the destruction of the heat exchanger At tempera...

Page 6: ...ng Fouling increases the susceptibility of corrosion Technical specifications 50671 50672 50673 50675 50676 Panels Thickness conductive panel 0 26 Thickness cover panel 1 0 Distance 2 1 Size 191 73 Nu...

Page 7: ...ce 2 1 Size 286 116 529 124 Number 40 50 30 40 50 60 Temperature range 195 225 Capacity 2 0 2 5 3 33 4 44 5 55 6 66 Operational pressure 30 Max flow rate min ab 200 ab 367 Max power kW 230 285 330 440...