background image

 

https://www.XPOtool.com 

 

Item 50671–50673, 50675–50687

 

Page 7 

 

The Tool Experts

 

 

  

 

08 2022-1

 

Connectors

 (

)

 

F1, F3

 

12.7 (½″)

 

25.4 (1″)

 

F2, F4

 

25.4 (1″)

 

Effective exchange surface

 (

)

 

ab. 0,69

 

ab. 0.92

 

ab. 1.15

 

ab. 0.64

 

ab. 0.96

 

Material

 

Stainless steel, copper

 

Circulation

 

F1 

 F3 / F4 

 F2

 

 

 

50682

 

50683

 

50684

 

50685

 

50686

 

50687

 

P

anel

s

 

Thickness conductive panel

 (

)

 

0.4

 

Thickness cover panel

 (

)

 

2.0

 

Distance

 (

)

 

2.1

 

Size

 (

)

 

286×116

 

529×124

 

Number

 

40

 

50

 

30

 

40

 

50

 

60

 

Temperature range

 (

)

 

-195–+225

 

Capacity

 (ℓ)

 

2.0

 

2.5

 

3.33

 

4.44

 

5.55

 

6.66

 

Operational pressure

 (

)

 

30

 

Max. flow rate

 (

min

)

 

ab. 200

 

ab. 367

 

Max. power

 (kW)

 

230

 

285

 

330

 

440

 

550

 

660

 

Connectors

 (

)

 

F1, F3

 

25.4 (1″)

 

F2, F4

 

Effective exchange surface

 (

)

 

ab. 1.28

 

ab. 1.60

 

ab. 1.80

 

ab. 2.4

 

ab. 3.0

 

ab. 3.6

 

Material

 

Stainless steel, copper

 

Circulation

 

F1 

 F3 / F4 

 F2

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Important notice:

 

 

The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction 
manual require the written permission of WilTec Wildanger Technik GmbH.

 

Summary of Contents for 50671

Page 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insi...

Page 2: ...entirely avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www...

Page 3: ...e heat exchangers It is the so called soldered plate heat exchangers that are preferred being characterized by the fact that the different plates are soldered with each other By this means you can ren...

Page 4: ...ted so that the plate heat exchanger can be ventilated and emptied The minimum distance for the mounting on the thermal insulation is 40 mm As for heat technical applications a vertical mounting posit...

Page 5: ...be ensured that there are no operating conditions being in contradiction to this assembly operation and maintenance manual The formation of ice causes the destruction of the heat exchanger At tempera...

Page 6: ...ng Fouling increases the susceptibility of corrosion Technical specifications 50671 50672 50673 50675 50676 Panels Thickness conductive panel 0 26 Thickness cover panel 1 0 Distance 2 1 Size 191 73 Nu...

Page 7: ...ce 2 1 Size 286 116 529 124 Number 40 50 30 40 50 60 Temperature range 195 225 Capacity 2 0 2 5 3 33 4 44 5 55 6 66 Operational pressure 30 Max flow rate min ab 200 ab 367 Max power kW 230 285 330 440...

Reviews: