background image

REMOTE CONTROL

TRANSFORMER 

Note: The transformer unit should be connected to the

mains supply through a fused double pole isolating switch

maximum 5 amps.

Min 6 inches

Installation Instructions

If working above Ground Floor level, appropriate safety precautions must be observed.

WARNING

EYE PROTECTION MUST BE WORN DURING ALL DRILLING AND CHISELLING OPERATIONS

Safety First

The Heat Recovery Ventilator is a ”SELV” (Safety Extra Low Voltage) ventilator which operates at 12 volts AC. Under no
circumstances must this be connected directly to the mains supply. Damage so caused is not covered by the warranty.
The low voltage used by the ventilator must be provided by the isolating transformer. A typical layout of installation is
shown below.

The Heat Recovery Ventilator can be used in any room which has an outside wall open to fresh air. It is particularly
useful in the bathroom, kitchen or laundry room where high levels of moisture are generated. It can also be used in the
lounge, dining room or any bedroom to provide a fresh air supply to reduce dust-mite, eliminate mould growth or
dampness and condensation and to provide warmed fresh air.

April 2000

These appliances are intended for connection to fixed wiring.

Check that the electrical rating shown on the transformer matches the mains supply.

All installation must be supervised by a qualified Electrician.

Installation and wiring must conform to current IEE Regualtions(UK), local or appropriate regulations 
(other countries)      

The  product must be supplied by a double pole isolating switch with a minimum contact gap of 3mm.

The product is double insulated and does not require earth connection. A parking terminal is provided to 
ensure continuity of external protective wiring only, and when used must comply with the relevant regulations

WARNING

THESE APPLIANCES ARE DOUBLE INSULATED AND DO NOT REQUIRE AN EARTH CONNECTION

If you  have any queries before installing this product or after it has been installed, please contact GDA 
Applied Energy, Customer Services - see back cover. Customers  outside the UK should contact their  
local Xpelair distributor.

Xpelair Heat Recovery Ventilation Range- XHR150PC and XHR150HP 

Xpelair Heat Recovery Unit  have the following features: XHR150PC 

Integral Pull Cord

Heat Recovery Ventilator 

VENTILATOR

Eclipse - Oxplaire  12/4/00  6:51 pm  Page 1

Summary of Contents for XHR150PC

Page 1: ...educe dust mite eliminate mould growth or dampness and condensation and to provide warmed fresh air April 2000 These appliances are intended for connection to fixed wiring Check that the electrical ra...

Page 2: ...an be adjusted by turning the thumbwheel as shown on page 2 We recommend that it is initially set to number 6 on the scale which is suitable for most locations Turning the thumbwheel clockwise decreas...

Page 3: ...ric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates a Survey the property carefully and identify the best site for the ventilator Condensatio...

Page 4: ...masonary does not fall injure people or damage property below e Measure the length of the hole between the outside brick face and inner plaster work Now cut the outer tube accurately to the required l...

Page 5: ...ive gently against the wall compressing the adhesive Then pull the tube into the room leaving the finisher in place Ensure that the finisher does not fall v Now manipulate the finisher to expand it ou...

Page 6: ...or in the direction you have determined for the transformer or remote control Fit screw plugs into the screw holes l Fit the wall plate onto the open end of the large tube fitted with the outside cowl...

Page 7: ...ble isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be following Suitably rated 2 core cable 3 mm electricians screw...

Page 8: ...wn on page 1 being extinguished p After the system has run for some time check the fan unit switches to boost by directing steam from a kettle over the remote control unit q The fan s continuous trick...

Page 9: ...depending on the location of the remote transformer humidity assembly in the room Fine tuning may be required for precise operation Clockwise allows boost to operate during darkness Anti clockwise pr...

Page 10: ...and service Customers outside UK see International below UK Xpelair have a comprehensive range of services including Free technical advice from Engineers on all aspects of ventilation Free design ser...

Reviews: