- 21 -
�
�
�
�
�
�
USE
• If the apparatus is equipped with the
following controls luminous:
A
= LIGHT
B
= OFF
C
= SPEED I
D
= SPEED II
E
= SPEED III
F
= AUTOMATIC STOP TIMER - 15 minutes
(*)
•
If your appliance does not have the
INTENSIVE
speed function, press key
E
for two seconds and it will be activated for
10 minutes after which it will return to the
previously set speed. When the function
is active the LED flashes. To interrupt it
before the 10 minutes have expired press
key
E
again.
•
By pressing key
F
for two seconds (with the hood switched off) the “
clean air
” function
is activated. This function switches the appliance on for ten minutes every hour at the first
speed. As soon as this function is activated the motor starts up at the first speed for ten
minutes, During this time key
F
and key
C
must flash at the same time. After ten minutes
the motor switches off and the LED of key
F
remains switched on with a fixed light until
the motor starts up again at the first speed after fifty minutes and keys
F
and
C
start to
flash again for ten minutes and so on. By pressing any key for the exclusion of the hood
light the hood will return immediately to its normal functioning (e.g. if key
D
is pressed
the “
clean air
” function is deactivated and the motor moves to the 2nd speed straight
away. By pressing key
B
the function is deactivated).
(*)
The “
automatic stop timer
” delays stopping of the hood, which will continue function-
ing for 15 minutes at the operating speed set at the time this function is activated.
• Active carbon/grease filter saturation:
- When button
A
flashes at a frequency of
2 seconds
, the
grease
filters must be
cleaned.
- When button
A
flashes at a frequency of
0.5 seconds
, the
carbon
filters must be
replaced.
After the clean filter has been replaced, the electronic memory must be reset by pressing
button
A
for approximately
5 seconds
, until the light on the button stops flashing.