Manual 0-4809
2-2
Introduction
2.04 Torch Specifications
Torch Configuration
Torch Head at 75° to
Torch Handle
Torch Leads Length
20 feet ( 6.1 m)
Ambient
Temperature
104° F
40° C
Torch Duty Cycle
100% @ 60 Amps
@ 400 scfh
Maximum Current
60 Amps, DC,
Straight Polarity
Voltage (V
peak
)
500V
Arc Striking Voltage
7kV
Type of Cooling
Ambient air and gas
stream through torch
Parts-in-Place:
Built-in Switch
in Torch Head
Gas Requirement:
Single Gas,
Compressed Air Only
Input
Gas Pressure
75 psi (5.2 bar) -
125 psi (8.6 bar)
Minimum Gas Flow
400 scfh / 6.6 scfm
(188.7 lpm)
Plasma Power
Supply Used With:
NXP35
SL60™ 1Torch™ Ratings for NXP35
2.05 System Contents
ITEMS
Description
Q'ty
Power Source Model NXP35
1
Torch Set
SL60™, with 20' leads
(6.1m)
1
Accessories &
Consumables
Air Regulator
Work Cable
Manual
Torch Electrodes
Torch Tips
1
1
1
2
3
Input Power
Cable For
Systems
1-1635-4 (CE)
2 Meter Cord With No
Plug
1
If you have questions or concerns regarding your sys-
tem, please contact:
Leengate Welding Group Ltd
Redfield Road
Lenton
Nottingham
NG7 2UJ
0044 (0) 115 986 7880
2.06 Transporting Methods
Lift unit with handle on top of case. Use handcart or
similar device of adequate capacity for transporting.
WARNINGS
ELECTRIC SHOCK can kill. DO NOT
TOUCH live electrical parts. Disconnect input
power from supply before moving the power
source.
FALLING EQUIPMENT can cause serious per-
sonal injury and equipment damage.
Summary of Contents for NXP35