![Xnexus NXP35 Operating Manual Download Page 16](http://html1.mh-extra.com/html/xnexus/nxp35/nxp35_operating-manual_3533426016.webp)
SERVICE
5-3
Manual 0-4809
2. Poor Work Lead connection.
a. Check the connection of the Work Lead to the
work piece.
Make a clean work cable
connection to the work-
piece or cutting table
Work Cable
And Clamp
Art # A-04389
3. Current sensor or PWM PCB faulty.
a. Return to an authorized service center for re-
pair.
F. Air flows continuously and torch switch latch
button doesn't work properly.
1. Torch Switch Latch button on front panel faulty.
a. Return to an authorized service center for re-
pair.
2. Control PCB faulty.
a. Return to an authorized service center for re-
pair.