6
PLEASE ENGAGE LOCAL PROFESSIONAL INSTALLER TO PERFORM
INSTALLATION. PLEASE ALWAYS FOLLOW LOCAL BUILDING
CODES, ELECTRICAL CODES AND LOCAL LAWS.
1.
Preliminary Checking:
1)
The ceiling structure should support at least
FOUR
times the total weight of the
lift and projector. Please reinforce additional supporting structure if needed.
2)
Please check the overall dimensions of the lift and ensure that there is sufficient
space above ceiling before installation.
3)
100mm (4″) clearances from all surrounding structures are recommended. The
minimum ceiling space required for the lift to install at ceiling is 1100mm (W) x
800mm (D) x 850mm (H). The installer must be accessible to every sides of the
lift in order to install it.
4)
Check the dimensions of the projector to be mounted within the available space.
5)
Determine the projector installation position based on projection screen location
and projector specifications.
6)
Confirm that there is adequate space for installation, operation and maintenance.
7)
Arrange the space for service and the access to the lift.
8)
Confirm height ofceiling with maximum travel of scissor lift.
9)
Physically check for any damages or loose parts on the lift.
2.
Guidelines for Installation:
1)
An access from above the lift with enough clearance to remove the top cover
should be provided in case of any service is required.
2)
Installer must ensure that all fasteners support have adequate strength to
securely support the scissor lift and projector.
3)
The lift must be installed in level from front-to-back and side-to-side.
4)
Make sure that the liftis level in all directions and weight should be shared
equally by all four threaded mounting rods.
5)
Bottom of the lift must be unobstructed after installation.
3.
Installation on Ceiling:
Summary of Contents for SC60
Page 1: ...0 Scissor Lift Model SC60 SC40 Installation Instructions...