39
DarkStar User Guide
3: Software
www.xkl.com
The following output is an example of an EDFA preamplifier configuration:
localhost>
enable
localhost#
configure
localhost CONF#
edfa west 0
localhost CONF-EDFA-WEST[0]#
do show edfa west 0
edfa west 0
Module is administratively down, amplification is down
Module identification data:
Manufacturer: RED-C Module Function Type: Preamplifier
Firmware Date: Jul 22 2009 Serial Number: 23197
Module operational data:
Control mode is automatic power control (APC)
Setpoint is 16.5 dBm
Module Alarms: ILD
Input Optical Power: -32.2 dBm
Output Optical Power: -54.5 dBm
Case temperature is 25.6 C
Pump laser:
Pump is enabled
Current 0.0 mA
Pin Alarms:
pump bias
localhost CONF-EDFA-WEST[0]#
control output power -5.0
mode p -5.0
localhost CONF-EDFA-WEST[0]#
no shutdown
localhost CONF-EDFA-WEST[0]# Amplifier edfa west 0 amplification up
localhost CONF-EDFA-WEST[0]#
exit
localhost CONF#
do show interfaces summary
Switch Interfaces Summary:
Admin Line Rate/kHz RxPow Ch. Alarms Last Line Chng
----------- -------- ----------- --- ------ --------------
----------
Client 0 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 1 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 2 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 3 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 4 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 5 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 6 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 7 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 8 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Client 9 Up LOS 10GE <-40.0(dBm) N/A Nt_Rdy 0:01:18:40
Wave East 4 Up Down 10GE -16.6(dBm) 54 None 0:01:18:40
Wave East 3 Up Down 10GE -17.0(dBm) 53 None 0:01:18:40
Wave East 2 Up Down 10GE -18.3(dBm) 52 None 0:01:18:40
Wave East 1 Up Down 10GE -17.0(dBm) 51 None 0:01:18:40
Wave East 0 Up Down 10GE -18.4(dBm) 50 None 0:01:18:40