XR Series Wireless Arrays
9
Connect the Cables
The XR-600 receives power and data on the GIGABIT1/PoE+
port.
If you have not already done so, cut an access hole for
the cable in the ceiling or wall and draw the cable(s) through.
GIGABIT1/PoE+
: Only compatible Xirrus-supplied power
injectors, or 802.3at PoE-compliant switches, may be used to
power the XR-600.
Connect the cable that carries power and data to this port. If you are using a Xirrus-supplied
injector, its CONNECT LED should light (for 30W and higher injectors, it is OK if it blinks).
If power is being properly supplied to the XR-600, the LEDs on its front will light and then
commence blinking in their boot pattern.
GIGABIT2
: (Optional) An additional data connection may be plugged into this port.
5.
Cut an access hole for the cable in the wall and draw the
cable(s) through.
6.
Align the two slots in the back of the XR-600 chassis shown
here with the corresponding tabs in the XR-600 mounting
plate.
7.
Push the XR-600 chassis up on the mounting plate tabs and
rotate the XR-600 to the right until it snaps in place.
8.
To secure the XR-600 to the mounting plate, feed a zip tie
through the hole in the top of the locking slug and the
matching hole in the wall mounting plate.
5