background image

High Performance Wireless Networks

XR Series

Wireless Arrays

QUICK INSTALLATION GUIDE

  XR-600 Series 

  March 20, 2014

Summary of Contents for XR Series

Page 1: ...High Performance Wireless Networks XR Series Wireless Arrays QUICK INSTALLATION GUIDE XR 600 Series March 20 2014 ...

Page 2: ... Please see Legal Notices Warnings Compliance Statements and Warranty and License Agreements in the Wireless Array User s Guide All rights reserved This document may not be reproduced or disclosed in whole or in part by any means without the written consent of Xirrus Inc Part Number 812 0085 007 Rev A March 20 2014 ...

Page 3: ...ou must provide a data connection from the switch to the injector as well as another cable from the injector s OUT port to the GIGABIT1 PoE port PoGE Injectors require an AC outlet See the PoGE Installation Guide for more information Optional GIGABIT2 Connection to this second data only Gigabit port provides additional bandwidth Use Cat 5E or Cat 6 cable NOTE The XR 600 must be connected to PoGE n...

Page 4: ...th the XR Series Identify new clips by their white studs don t use old clips whose studs aren t white For a locked installation supply a zip tie small lock or other locking hardware Phillips head screwdriver to attach the wall mounting plate or ceiling locking plate to the XR 600 mounting plate Choose a Suitable Location The XR 600 can be installed on the ceiling or on a wall or may be placed on a...

Page 5: ...acket to the XR 600 mounting plate and install the XR 600 the hole in the top of the locking slug will align with the hole on the tab in the locking plate or wall bracket You can then use a customer supplied zip tie lock or other locking hardware to permanently secure the AP to the mounting plate Install Mounting Hardware and XR 600 The XR 600 can be installed directly on a normal ceiling or on a ...

Page 6: ...screws after mounting 1 Mark the location for the two mounting screws 3 5 8 9 cm apart on center You may use the Direct Mounting Template on page 13 2 Install two screws in the ceiling so that they protrude 1 8 32 cm between the mounting surface and the head of the screw 3 Align the holes in the back of the XR 600 over the screws protruding from the ceiling Push the XR 600 chassis up on the screw ...

Page 7: ...he grid s slot easiest to do at an intersection position them for the two holes in the T Bar Bracket and twist bolts till snug in the slot Secure bracket with nuts bolts pointing down Attach the Mounting Plate to bracket with supplied nuts Skip the next 2 steps 4 If using T Bar clips use the four holes on the XR 600 mounting plate to mark the placement of the four T bar clips on the metal ceiling ...

Page 8: ...cure it to the four posts using the nuts provided Tighten the nuts to 10 12 lbf ft 1 38 1 66 kgf m but do not over tighten 7 Align the two slots in the back of the XR 600 chassis shown at right 8 with the corresponding tabs in the XR 600 mounting plate shown here 9 Push the XR 600 chassis up on the mounting plate tabs and rotate the XR 600 to the right until it snaps in place 10 To secure the XR 6...

Page 9: ...the XR 600 mounting plate as shown here NOTE Only use the screws provided in the accessory kit Other screws that may appear equivalent in size may damage the XR 600 mounting plate 3 Use the four holes on the XR 600 mounting plate to mark the placement of four screws to install in the ceiling You must supply four screws of an appropriate type for your ceiling construction type 4 Drill and prepare h...

Page 10: ... wall mount bracket over the corresponding mounting plate holes NOTE Use only the screws provided in the accessory kit Other screws that seem equivalent in size may damage the mounting plate 2 Use the three screws provided in the accessory kit to attach the wall mounting plate to the XR 600 mounting plate as shown here 3 Use the Wall Mounting Bracket as a template and mark the locations on the wal...

Page 11: ...ors it is OK if it blinks If power is being properly supplied to the XR 600 the LEDs on its front will light and then commence blinking in their boot pattern GIGABIT2 Optional An additional data connection may be plugged into this port 5 Cut an access hole for the cable in the wall and draw the cable s through 6 Align the two slots in the back of the XR 600 chassis shown here with the correspondin...

Page 12: ...ity it will automatically contact Xirrus for cloud based zero touch provisioning per your settings install the latest applicable license and upgrade the AP to the latest software version as appropriate XMS Enterprise Also available as a cloud deployed solution XMS 9000 CL x This platform automatically detects and provisions new Xirrus devices deployed in your network via a similar zero touch provi...

Page 13: ...t to the slot for the locking slug opposite the side with the Gigabit ports as shown Use the reset button as follows Unplug the cable from the GIGABIT1 POE port Use a paper clip to depress the reset button there should be a faint click and hold it Plug the cable back in and continue to keep the button pressed for 10 seconds This triggers the factory default reset during the boot process 7 ...

Page 14: ...XR Series Wireless Arrays 2 12 Drawings XR 600 Mounting Bracket Wall Mounting Bracket 8 ...

Page 15: ...XR Series Wireless Arrays 3 13 Direct Mounting Template ...

Page 16: ...s Wireless Arrays 4 14 Physical Environmental Specifications Dimensions WxDxH 7 70 x 7 70 x 1 96 in 19 56 x 19 56 x 4 98 cm Weight 1 6 lb 0 73 kg Operating Temperature 0 55C 32 131F 0 90 humidity non condensing ...

Page 17: ......

Page 18: ...rporate Center Drive Thousand Oaks CA 91320 USA To learn more visit xirrus com or email info xirrus com 201 Xirrus Inc All Rights Reserved The Xirrus logo is a registered trademark of Xirrus Inc All other trademarks are the property of their respective owners Content subject to change without notice 812 0085 007 Rev A ...