4-1-3 Edit parameter screen
Screen Elements:
Title
Four text description
Four unit description
Four data setting units and one screen jump key
1.
First, design the title
Add one
in the screen, modify the content as “Parameter”, choose “Inverse”, and set the
font.
Drag the title to the proper position refers to the following diagram.
2.
Next, design the other elements:
Add
four
icons, set the property and content: “ Frequency”, “Flow Setting”, “Temperature
Setting”, “Length Setting”; Modify the font.
Add four “Register” icons, set separately their properties: Register ID separately are: D 500, D
502, D504, D508, Digit is 4; Decimal is 1; At the same time choose ‘Set’, the left are defaulted;
Place them in the proper position
Then, add four
icons in the screen, set the content as “Hz”, “%”, “ºC”, and “m”; modify the
font, place them in the proper position, see the following diagram:
Add
one
icon in the screen, modify the content as “Back”, set the font; set its functions
as screen jump, jump to screen 1, then place in the right button.
Please refer to the following diagram:
3. Finish editing [Parameter] screen.