![Xinje XP3-16R Manual Download Page 37](http://html1.mh-extra.com/html/xinje/xp3-16r/xp3-16r_manual_3443707037.webp)
XP3 PLC/HMI Hardware Manual
Page 37 of 42
LMAN007_R2V2
2.
Set the left elements:
Add
seven in the screen.
Set the font and content, the content is “Status Indication”.
Set the left six texts’ property: The content is: “Power”, “Run”, “Light”, “Auto Wind”, “Up”,
“Down”.
Modify the font and choose “Underline”. Place in the proper position.
Then add six indicator lamps
, place by the right of the corresponding text. Set the
property separately:
Power:
coil
M0
Run:
coil
M1
Light:
coil
M10
Auto Wind:
coil
M11
Up:
coil
M12
Down:
coil
M13
Add
an icon, set its property: Register ID is D10; add the display content shown below:
Then place it by the right of ‘Status Indication’:
Next, add two text units, one register, set the property as following:
Text 1 content is “Temp.”
Text 2 is “ºC”, they both choose inverse.
Register ID is D 100, the display bits is 4, the decimal bit is 1, also choose inverse, the
left are defaulted.
Place them in the proper position, used as temperature indication.
Place keys in the screen. Modify the first content as “Stop”, set the font and size; Set the
touch key’s function parameters: Screen Jump, Jump to screen 1, then place in the right
bottom. Modify the second content as “Back”. Set the font and size. Set the touch key’s
function parameters: Set the coil; Coil number: M51; Operating item: Momentary ON.