V5 series inverter
73
Instruction
Instruction
Instruction
Instructionssss of
of
of
of the
the
the
the functions
functions
functions
functions shown
shown
shown
shown in
in
in
in Tabel
Tabel
Tabel
Tabel 4-6
4-6
4-6
4-6::::
0
0
0
0
:
Inverter
Inverter
Inverter
Inverter running
running
running
running
(
RUN
RUN
RUN
RUN
)
....
Inverter is in the running status and the terminal outputs indication signal.
1
1
1
1
:
Frequency
Frequency
Frequency
Frequency arriving
arriving
arriving
arriving signal
signal
signal
signal
(
FAR
FAR
FAR
FAR
)
....
Refer to P4.12 for function instruction.
2
2
2
2
:
Frequency
Frequency
Frequency
Frequency detection
detection
detection
detection threshold
threshold
threshold
threshold
(
FDT1
FDT1
FDT1
FDT1
)
....
Refer to P4.11~ P4.12 for function instruction.
3
3
3
3
:
Frequency
Frequency
Frequency
Frequency detection
detection
detection
detection threshold
threshold
threshold
threshold
(
FDT2
FDT2
FDT2
FDT2
)
. Refer to P4.13
~
P4.14 for function instruction.
4
4
4
4
:
Overload
Overload
Overload
Overload pre-alarm
pre-alarm
pre-alarm
pre-alarm
(
OL
OL
OL
OL
)
....
If the output current is higher than the value defined by P4.24 and the time is longer than the
value defined by P4.25, the inverter will output indicate signals. This function is mainly used in pre-alarm.
5
5
5
5
:
Inverter
Inverter
Inverter
Inverter under
under
under
under voltage
voltage
voltage
voltage locking
locking
locking
locking
(
LU
LU
LU
LU
)
....
While inverter is in running process, if the DC injection bus voltage is lower than
the limit value, “E-11” will be displayed in LED and indicate signal will be output.
6
6
6
6
:
External
External
External
External fault
fault
fault
fault stop
stop
stop
stop
(
EXT
EXT
EXT
EXT
)
....
An indicate signal will be output if inverter outputs trigging signal caused by external fault.
7
7
7
7
:
Output
Output
Output
Output frequency
frequency
frequency
frequency arrive
arrive
arrive
arrive upper
upper
upper
upper limit
limit
limit
limit
(
FH
FH
FH
FH
)
....
An indicate signal will be output if reference frequency≥upper limit of
frequency and the running frequency arrives the upper limit of frequency.
8
8
8
8
:
Output
Output
Output
Output frequency
frequency
frequency
frequency arrive
arrive
arrive
arrive lower
lower
lower
lower limit
limit
limit
limit
(
F
F
F
FL
L
L
L
)
....
An indicate signal will be output if reference frequency
≤
lower limit of
frequency and the running frequency is lower than low limit of frequency.
9
9
9
9
:
Inverter
Inverter
Inverter
Inverter zero
zero
zero
zero speed
speed
speed
speed running
running
running
running
. The output frequency of inverter is 0 , while the terminal will output indicate signal when
inverter is in running status.
10
10
10
10
:
Simple
Simple
Simple
Simple PLC
PLC
PLC
PLC Pause
Pause
Pause
Pause running
running
running
running finished
finished
finished
finished....
An indicate signal (single pulse signal, 500ms width) will be output if the present
stage of PLC operation is finised.
11:
11:
11:
11: PLC
PLC
PLC
PLC is
is
is
is finished
finished
finished
finished after
after
after
after one
one
one
one cycle
cycle
cycle
cycle running.
running.
running.
running.
An indicate signal (single pulse signal, 500ms width) will be output if one
cycle running of simple PLC is finished.
12
12
12
12
:
Specified
Specified
Specified
Specified counting
counting
counting
counting value
value
value
value arriving
arriving
arriving
arriving
13
13
13
13
:
Mid
Mid
Mid
Mid counting
counting
counting
counting value
value
value
value arriving
arriving
arriving
arriving
12,13 refer to P4.22~P4.23 for function instruction.
1
1
1
14
4
4
4
:
Inverter
Inverter
Inverter
Inverter Ready
Ready
Ready
Ready running
running
running
running finished
finished
finished
finished
(
RDY
RDY
RDY
RDY
)
.If RDY signal is output, it means the drive has no fault, its DC bus voltage is
normal and it can receive starting command.
1
1
1
15
5
5
5
:
Inverter
Inverter
Inverter
Inverter fault.
fault.
fault.
fault.
If there is fault with inverter, indicate signal will be output.
16
16
16
16
:
Start
Start
Start
Start frenquence
frenquence
frenquence
frenquence running
running
running
running time
time
time
time
17
17
17
17
:
Start
Start
Start
Start DC
DC
DC
DC injection
injection
injection
injection braking
braking
braking
braking time
time
time
time
18
18
18
18
:
Stop
Stop
Stop
Stop braking
braking
braking
braking time
time
time
time
19
19
19
19
:
Upper
Upper
Upper
Upper and
and
and
and lower
lower
lower
lower limits
limits
limits
limits of
of
of
of traverse
traverse
traverse
traverse operating
operating
operating
operating frequency
frequency
frequency
frequency....
An indicate signal will be output if the traverse operating
frequency calculated by central frequency is higher than upper limit of frequency (P0.19) or lower than the lower limit of
frequency (F0.20), as shown in Fig. 4-25.
Fig.
Fig.
Fig.
Fig.4-25
4-25
4-25
4-25 Upper
Upper
Upper
Upper and
and
and
and lower
lower
lower
lower limits
limits
limits
limits of
of
of
of traverse
traverse
traverse
traverse operating
operating
operating
operating frequency
frequency
frequency
frequency
7
Output frequency arrive upper limit
(
FH
)
18
Stop braking time
8
Output frequency arrive lower limit
(
FL
)
19
High and lower limits of traverse operating frequency
9
Inverter zero speed running
20
set running time arriving
10
Simple PLC Pause running finished
21