V5 series inverter
63
9
:
RS485
-
CI-Increase/Decrease key reference
10
:
RS485
+
CI
+
External pulse reference
11
:
RS485
-
CI
-
External pulse reference
12
:
RS485
+
VI
+
External pulse reference
13
:
RS485
-
VI
-
External pulse reference
14
:
VI
+
CI
+
Increase/Decrease key reference
+
Digital setting
P0.02
15
:
VI
+
CI
-
Increase/Decrease key reference
+
Digital setting P0.02
16
:
MAX
(
VI
,
CI
)
17
:
MIN
(
VI
,
CI
)
18
:
MAX
(
VI
,
CI
,
PLUSE
)
19
:
MIN
(
VI
,
CI
,
PLUSE
)
20
:
VI
,
CI is active
,
VI is priority
LED
LED
LED
LED unit
unit
unit
unit’’’’ssss place
place
place
place
0
:
All the parameters are allowed modifying.
1
:
Only P3.01 can be modified.
2
:
Only P0.02 and P3.01 can be modified.
LED
LED
LED
LED ten
ten
ten
ten’’’’ssss place
place
place
place
0
:
Disabled
1
:
Restore to factory setting
2
:
Clear fault record
Note
Note
Note
Note
:
(1) The factory setting of P3.01 is 0 and allow all the parameters to be modified.After modifying this parameter,
please set it as 0 if you want to modify other parameters.Also ,you can set protective grade.
(2) P3.01 will be changed to 0 automatically after restoring to factory setting.
0
0
0
0
:
Disabled
Disabled
Disabled
Disabled
1
1
1
1
:
Parameter
Parameter
Parameter
Parameter up
up
up
up load
load
load
load
:
Up load the parameters from inverter to remote opration panel.
2
2
2
2
:
Parameter
Parameter
Parameter
Parameter down
down
down
down load
load
load
load
:
Down load the parameters from remote operation panel to inverter.
Note
Note
Note
Note
:
This
This
This
This function
function
function
function is
is
is
is still
still
still
still in
in
in
in devel
devel
devel
develop
op
op
oping
ing
ing
ing....
0
0
0
0
:
Disabled
Disabled
Disabled
Disabled
1
1
1
1
:
Enabled
Enabled
Enabled
Enabled
Inverter can regulate output voltage through detecting load current to achieve energy-saving when the motor running
without load or with light load. Auto energy-saving is suitable for the application with steady load and speed.
AVR function points to regulating voltage automatically.When the input voltage of inverter fluctuates, AVR function can
keep it steady.
In Dec-to-stop process, if AVR is disabled, the Dec time is short and the running current is big; if AVR is enabled, the motor
decelerates steadily, the running current is small and the Dec time is prolonged.
0
0
0
0
:
Disabled
Disabled
Disabled
Disabled
1
1
1
1
:
Enabled
Enabled
Enabled
Enabled
2
2
2
2
:
Disabled
Disabled
Disabled
Disabled in
in
in
in Dec
Dec
Dec
Dec process
process
process
process
This function can make suitable regulation for inverter’s output frequency according to the load changes, and control the
P3.01
P3.01
P3.01
P3.01
Parameter
Parameter
Parameter
Parameter initialization
initialization
initialization
initialization
locking
locking
locking
locking up
up
up
up
Range
Range
Range
Range
:
LED
LED
LED
LED unit
unit
unit
unit’’’’ssss place
place
place
place 0~2
0~2
0~2
0~2
,
LED
LED
LED
LED ten
ten
ten
ten’’’’ssss place
place
place
place 0~2
0~2
0~2
0~2
00
00
00
00
P3.02
P3.02
P3.02
P3.02
Parameter
Parameter
Parameter
Parameter copy
copy
copy
copy
Range
Range
Range
Range
:
0
0
0
0,,,,1
1
1
1,,,,2
2
2
2
0
0
0
0
P3.03
P3.03
P3.03
P3.03
Auto
Auto
Auto
Auto energy-saving
energy-saving
energy-saving
energy-saving function
function
function
function
Range
Range
Range
Range
:
0
0
0
0,,,,1
1
1
1
0
0
0
0
P3.04
P3.04
P3.04
P3.04
AVR
AVR
AVR
AVR funciton
funciton
funciton
funciton
Range
Range
Range
Range
:
0
0
0
0,,,,1
1
1
1,,,,2
2
2
2
0
0
0
0
P3.05
P3.05
P3.05
P3.05
Gain
Gain
Gain
Gain of
of
of
of slip
slip
slip
slip compensation
compensation
compensation
compensation
Range
Range
Range
Range
:
0
0
0
0
~
150(
150(
150(
150(
%
))))
0(
0(
0(
0(
%
))))