(2)
data collect: use history data map to collect the data every 1 second, use PSB300 to control if it is need
to collect.
Click
,add it in the screen, change the “trend source” tab.
Next, change the display tab: page data is 5, control is PSB300.
Change the save tab: save the data in the registers start from PSW400.
Add a button, to control the stop and start of the collection process. The button is related to PSB300.
Page data:5, show 5 numbers each screen
Total data:10, it can collect 2 screens data
Pick period: 1 second, collect the data every
1 second.
Control:PSB300, control the ON/OFF of the
data collection by PSB300
Summary of Contents for TH465-M
Page 1: ...TH series Touch Screen User s manual Xinje Automation Co Ltd...
Page 2: ......
Page 6: ......
Page 19: ...l Please dispose the TH as industry waste Disposal Caution...