DP-708/DP-5022 series stepper driver
12
F3-00
External communication monitoring
F4-00
Forced enable
4-4-1
.
Check System Information
Press the STATUS/ESC key to select the auxiliary function mode. Set the group No.
to 0 to check system information. Press INC or DEC key to select different No., and
press and hold ENTER key to check current information. Press STATUS/ESC key to
return.
Information No.:
Code
Description
Code
Description
F0-00
Driver Serial No.
F0-01
Type
F0-02
Date: Year
F0-03
Date: Month
F0-04
Date: Day
F0-05
Software Version
F0-06
Hardware Version
4-4-2
.
Check Alarm Information
Set group No. to 1 in auxiliary function and enter alarm information state.
The following steps show how to check alarm information.
1. Press STATUS/ESC key to select Auxiliary Function.
2. Press INC or DEC key to set group No. to 1, and press ENTER key.
3. Press INC, DEC or ENTER key to modify the No.
4. Press ENTER key, display corresponding alarm information.
Code
Description
Unit
Modbus
address
F1-00
Current alarm code
1
※
0x0305
F1-01
Current warn code
2
※
0x0306
F1-02
Alarm/warn code 1 when alarm
0x0307
F1-03
U phase current when alarm
A
0x0308
F1-04
V phase current when alarm
A
0x0309
F1-05
Effective current values when alarm
A
0x030A
F1-06
Bus voltage when alarm
V
0x030B
F1-07
Module temperature when alarm
℃
0x030C
F1-08
Motor speed when alarm
rpm
0x030D
F1-09
Alarm/warn code 2 when alarm
0x030E
F1-10
Alarm/warn code 3 when alarm
0x030F
F1-11
Alarm/warn code 4 when alarm
0x0310
F1-12
Alarm/warn code 5 when alarm
0x0311
F1-13
Alarm/warn code 6 when alarm
0x0312
F1-14
Alarm/warn code 7 when alarm
0x0313
1
※
: When F1-00
=
0,
indicates that there is no alarm.
2
※
: When F1-01
=
0,
indicates that there is no warn.