1.Features: 

  Mainly monitor and control indoor space, generally set as Motion zone.   

    When human body enters into etecting area, the sensor will transmit alarm signals to the alarm host.   

2.Specifications: 

  Operating power: 9V alkaline battery   

  Emitting distance: 

100m (in open area) 

  Service life: 

1 year 

  Detecting distance: 110° 10×10m 

3.Installation and Usage 

  Fix the bracket on suitable wall surface or in wall corner at a distance of 2~2.4m above the ground;   

  Open the sensor shell to connect the batteries well and adjust jumper line (short circuit “5S”: The sensor will 

detect once every 5 seconds; short circuit “5MIN”: The sensor will detect once every 5 minutes;   

 S

uggestion: short circuit “5S” for testing and “5MIN” for normal use; 

 

  Fix the sensor onto the bracket;       

  Adjust the sensor to a proper angle and then slide the power switch on the side to “ON”, and it will enter into 

the normal working state after 30 seconds;   

  Upon the working light flashes frequently in green, please replace the batteries. 

4.How to program 

Please refer to the descriptions of 3.2.13 

Program Sensor

in page4. 

Note:   

 

You can only add 1 wireless wide-angle PIR sensor each time, totally 4 available to be added. 

 

Each serial number is available to study 1 wireless wide-angle PIR sensor, the latter configured wireless 
wide-angle PIR sensor will be workable and the former one becomes not workable automatically.   

 

Wireless Indoor Siren   

1. Functions Features: 

1.1 Work with alarm host, wireless receiving alarm signals, spot alarming with sound and flash   
1.2 With power plug, usually for indoor use. 

 

2. Specifications: 

2.1 Operating Power: 100—240VAC                                       
2.2 Receiving Distance:≥100 M

In open area

 

 

3. Installation and Usage:   

 

3.1 Plug the wireless siren into suitable indoor power socket   
3.2 Suggestion: Generally around 1.8M from the ground   

D0 

D3

0 2 1

Jump Line

Learning Emitting Switch

Power Switch
Down/Off
Up/On

Low-Votage 

     Light

Lens

Install the bracket

Fix the PIR by pushing
 it downwards

Wall

Keep the switch "on"

O

n

 / O

ff

Wall

Wall

Working Light

Summary of Contents for XSJ-8088

Page 1: ...less ding dong doorbell Door chime function during disarm status when open door host panel will sound fast bi bi bi to remind you Support CID protocol Store up to 100 alarm records and 100 arm disarm information Dual network and GSM network alarm host can send alarm info by SMS or phone call PSTN network alarm host can only send alarm info by phone call Dual network and GSM alarm host can arm disa...

Page 2: ... Emergency zone Detecting the space like Emergency area such as emergency distress medical rescue gas leakage and fire alarm etc this zone keep 24 hour monitoring status automatically Generally use panic button wireless gas sensors and wireless smoke sensors 1 3 Modes of arming 1 3 1 Away Arm mode Once any detectors in perimeter zones or motion zones get triggered the host will alarm immediately a...

Page 3: ...ll resume to the standby mode you can press to adjust programming info Or to find alarming info 3 The detailed menus in the SET are as below Main menu Sub Menu1 Sub Menu2 Sub Menu3 Sub Menu4 Remark Set Time Set time Hour minute second Set Date Set date Year Month Day Week Auto dialer s Call center Personal Nbr SMS phone no SMS reportng Alarming tele Number Pls notes Lanline host panel only with Su...

Page 4: ...eps need you to set for GSM host panel and Dual network host panel in menu Auto Dialer s Press to select the report method SMS Phone No for voice alarming SMS reporting for SMS alarming Notes if you choose SMS Reporting it will just sent to mobile numbers not include home phone numbers Press ENT to confirm each phone telephone mobile number 4 Entry delay This is for setting delay time of disarming...

Page 5: ...ere has 31 zonesfor your settings 29 wireless zones Each zone supports up to 4 sensors and 2 dedicated zones for remotes Supports up to 4 remotes or wireless keypads per zone Each zone needs to setup Zone Type Bypass Zone Entry Delay Zone type Zone type 2 1 0 and 2 means motion zone 1 means perimeter zone 0 means emergency zone sensor type normally 2 digits Sensor type Sensor name Sensor type Sens...

Page 6: ...rresponding disarm button and the host will beep twice to successfully complete the operation By Host panel Keypad ESC master code ENT the host will beep twice to successfully complete the operation Emergency By wireless remote Press Emergency key and the host will alarm immediately By host panel Keypad press and the host will alarm immediately Telephone alarm After receiving the call you will hea...

Page 7: ...panel only Disarm by SMS You can edit SMS XXXXXXCF to host panel the host panel would disarm automatically when getting this SMS and also will message back to mobile Disarm successfully Notes during opeartion Alarm phone dialing it will dial one group by one group if successfully get through won t dial again for the group which didn t get through will dial 3 times in total Exit delay during exit d...

Page 8: ...ansmit the alarm signals to the alarm host 2 Specifications Operating power 23A 12V alkaline battery Frequency 433MHZ Emitting distance 100m in open area Service life 1 year Alarm Distance 4cm 3 Installation and Usage Fix the part of magnet onto the door frame in a position of 1 6m above the ground to prevent any children from bumping onto it Fix the part of emitting onto the door frame make sure ...

Page 9: ...seconds Upon the working light flashes frequently in green please replace the batteries 4 How to program Please refer to the descriptions of 3 2 13 Program Sensor in page4 Note You can only add 1 wireless wide angle PIR sensor each time totally 4 available to be added Each serial number is available to study 1 wireless wide angle PIR sensor the latter configured wireless wide angle PIR sensor will...

Page 10: ...e keypad of the alarm host 3 One siren can be studied to at most 10 wireless alarm hosts multi wireless sirens are available to be added for each alarm host 学习按键的英文是 STUDY BUTTON Preview of how to activate and deactivate Basic accessories and Optional accessories Type Zone No Max no to be programmed How to activate How to deactivate Basic accessories Remote 00 01 8 1 SET Programming code Program s...

Page 11: ...elephone Fail to operate according to the operation instruction of the telephone alarm Follow the below instructions after answering the alarm phone calls and hearing the recorded message See 2 5 Operation Telephone alarm The host does not alarm after the detector is triggered in arm state 1 Caused by the functions of arm mode Armed Away and Armed Home 2 Have already setup time for Entry Delay or ...

Page 12: ...vent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting and accelerating to age Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the thieves from finding them Regular testing is necessary for finding and resolving problems in time Regularly check the batteries in all wirel...

Reviews: