Xilong Electronics XSJ-8088 Manual Download Page 11

Wireless 
Curtain PIR 
sensor 

11~20 

1) Same as above 
2) Trigger the PIR sensor by 
pressing  ”Learning  Emitting  Switch”  on 
the panel twice successively 

Same as above 

Wireless 
Indoor siren 

N/A 

—— 

1) After  connecting  to  the  power,  press 

the “learning switch on the side of the 
siren 

2) Press“ ” key on the alarm host, then 

disarm b keypad on the alarm host 

3) Light on the siren flashes 5 times and 

then off indicates successful activating 

After  connecting  to  the  power,  keep 
pressing  the  “Learning”  switch  on  the 
side  of  the  siren  for  5  seconds  and 
release,  light  on  the  siren  flashes  2 
times  and  then  off  indicate  successful 
deavtivating 

Optional 

Accessories 

Wireless 
Gas alarm 

02~10 

1)  Same as above 
2) 

Trigger wireless gas alarm by 

releasing  smoke,  the  host  LCD  will 
display “Success” 

Same as above 

Wireless 
Smoke 
Sensor 

02~10 

1) 

Same as above 

2) 

Press  any  key  on  the  remote 
controller  twice  successively,  the 
host LCD will display ”success” 

Same as above 

Remote 
Keypad 

00

01 

1) 

Same as above 

2) 

Press  any  key  on  the  remote 
controller  twice  successively,  the 
host LCD will display ”success” 

Same as above 

Wireless 
Outdoor 
Siren 

N/A 

—— 

Same as wireless indoor siren 

Same as wireless indoor siren 

 

Common Problems and Solutions 

Symptoms of Faults 

Possible Cause 

Solution 

The alarm host goes off   
immediately after connected to 
the power 

The telephone incoming line has 
not been connected or not well 
connected.   

Connect the telephone incoming line well.   

The alarm host can’t 
automatically record or can’t   
record completely 

The record switch is not on;   
The Record key is being pressed 
while recording 

1.

 

Slide the record switch to “ON”;   

2.

 

Keep pressing the RECORD key while recording.   

Repeatedly  receiving  the  alarm 
telephone 

Fail  to  operate  according  to  the 
operation 

instruction 

of 

the 

telephone alarm 

Follow  the  below  instructions  after  answering  the  alarm 
phone calls and hearing the recorded message:   
(See 2.5 Operation ---

 Telephone alarm

The  host  does  not  alarm  after 
the  detector  is  triggered  in  arm 
state 

1.  Caused  by  the  functions  of  arm 

mode (Armed Away and Armed 
Home); 

2. Have already setup time for Entry 

Delay or Exit Delay 

1.“Armed  Away”  mode:  the  alarm  goes  off  when  any 

sensor is triggered;   

2.  “Armed  Home”  mode:  the  alarm  goes  off  when  any 

sensor  in  1

st

  Defense  Line  is  triggered  and  it  won’t 

alarm when any sensor in 2

st

 Defense Line is triggered   

3. Program to adjust the time for Entry Delay or Exit Delay 

The PIR sensor doesn’t work 

1.  Not connected to the power 
2.  Port  of  the  detector  is  in  the 

power-down mode.   

1. 

Open  the  sensor  shells  to  install  the  batteries  well 
and slide the power switch to “On”;   

2. 

“5S”: detect once every 5 seconds; 

“5MIN”: detect once every 5 minutes; 

The  detecting  distance  of  PIR 
sensor gets shorter 

The  ambient  temperature  in  the 
detecting area is too high.   

When  the  ambient  temperature  in  the  detecting  area 
exceeds  the  human  body  temperature,  the  detecting 
distance will get shorter, it’s normal.   

The  host  does  not  alarm  after 
the new added wireless detector 
is triggered.   

Failed  to  follow  the  operation 
instruction  of  “Adding  and  deleting 
sensors”  to  add  the  new  wireless 
sensor 

Follow  the  operation  instruction  of  “How  to  program”  to 
activate the new wireless sensor 

The 

PIR 

sensor 

flashes 

frequently in green.   

Batteries are running out.   

Replace with new batteries of the same specification.   

The  door  magnetic  sensor 
indicator  flashes  frequently  in 
green after alarming. 

Batteries are running out. 

Replace with new batteries in the same specification. 

The  distance  of  the  remote 
controller gets shorter.   

Batteries are running out. 

Replace with new batteries in the same specification. 

 

Summary of Contents for XSJ-8088

Page 1: ...less ding dong doorbell Door chime function during disarm status when open door host panel will sound fast bi bi bi to remind you Support CID protocol Store up to 100 alarm records and 100 arm disarm information Dual network and GSM network alarm host can send alarm info by SMS or phone call PSTN network alarm host can only send alarm info by phone call Dual network and GSM alarm host can arm disa...

Page 2: ... Emergency zone Detecting the space like Emergency area such as emergency distress medical rescue gas leakage and fire alarm etc this zone keep 24 hour monitoring status automatically Generally use panic button wireless gas sensors and wireless smoke sensors 1 3 Modes of arming 1 3 1 Away Arm mode Once any detectors in perimeter zones or motion zones get triggered the host will alarm immediately a...

Page 3: ...ll resume to the standby mode you can press to adjust programming info Or to find alarming info 3 The detailed menus in the SET are as below Main menu Sub Menu1 Sub Menu2 Sub Menu3 Sub Menu4 Remark Set Time Set time Hour minute second Set Date Set date Year Month Day Week Auto dialer s Call center Personal Nbr SMS phone no SMS reportng Alarming tele Number Pls notes Lanline host panel only with Su...

Page 4: ...eps need you to set for GSM host panel and Dual network host panel in menu Auto Dialer s Press to select the report method SMS Phone No for voice alarming SMS reporting for SMS alarming Notes if you choose SMS Reporting it will just sent to mobile numbers not include home phone numbers Press ENT to confirm each phone telephone mobile number 4 Entry delay This is for setting delay time of disarming...

Page 5: ...ere has 31 zonesfor your settings 29 wireless zones Each zone supports up to 4 sensors and 2 dedicated zones for remotes Supports up to 4 remotes or wireless keypads per zone Each zone needs to setup Zone Type Bypass Zone Entry Delay Zone type Zone type 2 1 0 and 2 means motion zone 1 means perimeter zone 0 means emergency zone sensor type normally 2 digits Sensor type Sensor name Sensor type Sens...

Page 6: ...rresponding disarm button and the host will beep twice to successfully complete the operation By Host panel Keypad ESC master code ENT the host will beep twice to successfully complete the operation Emergency By wireless remote Press Emergency key and the host will alarm immediately By host panel Keypad press and the host will alarm immediately Telephone alarm After receiving the call you will hea...

Page 7: ...panel only Disarm by SMS You can edit SMS XXXXXXCF to host panel the host panel would disarm automatically when getting this SMS and also will message back to mobile Disarm successfully Notes during opeartion Alarm phone dialing it will dial one group by one group if successfully get through won t dial again for the group which didn t get through will dial 3 times in total Exit delay during exit d...

Page 8: ...ansmit the alarm signals to the alarm host 2 Specifications Operating power 23A 12V alkaline battery Frequency 433MHZ Emitting distance 100m in open area Service life 1 year Alarm Distance 4cm 3 Installation and Usage Fix the part of magnet onto the door frame in a position of 1 6m above the ground to prevent any children from bumping onto it Fix the part of emitting onto the door frame make sure ...

Page 9: ...seconds Upon the working light flashes frequently in green please replace the batteries 4 How to program Please refer to the descriptions of 3 2 13 Program Sensor in page4 Note You can only add 1 wireless wide angle PIR sensor each time totally 4 available to be added Each serial number is available to study 1 wireless wide angle PIR sensor the latter configured wireless wide angle PIR sensor will...

Page 10: ...e keypad of the alarm host 3 One siren can be studied to at most 10 wireless alarm hosts multi wireless sirens are available to be added for each alarm host 学习按键的英文是 STUDY BUTTON Preview of how to activate and deactivate Basic accessories and Optional accessories Type Zone No Max no to be programmed How to activate How to deactivate Basic accessories Remote 00 01 8 1 SET Programming code Program s...

Page 11: ...elephone Fail to operate according to the operation instruction of the telephone alarm Follow the below instructions after answering the alarm phone calls and hearing the recorded message See 2 5 Operation Telephone alarm The host does not alarm after the detector is triggered in arm state 1 Caused by the functions of arm mode Armed Away and Armed Home 2 Have already setup time for Entry Delay or ...

Page 12: ...vent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting and accelerating to age Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the thieves from finding them Regular testing is necessary for finding and resolving problems in time Regularly check the batteries in all wirel...

Reviews: