SP605 Hardware User Guide
43
UG526 (v1.9) February 14, 2019
Detailed Description
FPGA INIT and DONE LEDs
The typical Xilinx FPGA power up and configuration status LEDs are present on the SP605.
The red INIT LED DS17 comes on momentarily after the FPGA powers up and during its
internal power-on process. The DONE LED DS2 comes on after the FPGA programming
bitstream has been downloaded and the FPGA successfully configured.
X-Ref Target - Figure 1-14
Figure 1-14:
FPGA INIT and DONE LEDs
Table 1-22:
FPGA INIT and DONE LED Connections
U1 FPGA Pin
Schematic Net
Name
Controlled LED
Y4
FPGA_INIT_B
DS17 INIT, Red
AB21
FPGA_DONE
DS2 DONE, Green
VCC2V5
VCC2V5
VCC2V5
INIT_B = 0, LED: ON
INIT_B = 1, LED: OFF
1
2
R70
27.4
1/16W
1%
1
2
R169
332
1/16W
1%
2
1
D
S
2
LED-GRN-
S
MT
1
2
R69
75.0
1%
2
1
D
S
17
LED-RED-
S
MT
FPGA_INIT_B
2
1
5%
1/16W
4.7K
R19
FPGA_DONE
UG526_14 _092409