NeuPanel-Mini Series 

Quick Start Guide

 

 
 

XILICA AUDIO DESIGN CANADA / ASIA / EUROPE 

 

Page | 8 

12. Connection Problems?  

Yellow Network Connection Indicator                                                                                    

While in 

Network View

 if there is a Yellow network connection indicator next to the Mini device 

model the device is connected/online - 

but Not Ready / Not Operational.

   

 

The three most common reasons for this Yellow connection indicator is the result of 

(1)

 A   

non-DHCP connection where multiple Mini control devices are in use and where each device 
needs a unique IP address manually assigned to it properly 

(2)

 Where a non-DHCP 

connected single Mini control device is not reverting to is default IP address and/or is holding 
onto its previous address and 

(3)

 Software/Firmware incompatibility.   

 

Solutions 

– 

(1)

 See instructions on 

Page 8 & 9

 below to Manually Assign IP Addresses to 

each of the multiple Mini devices 

(2)

 Reset the Mini control to its default IP address prior to 

powering up the Mini device as recommended and described on 

Page 5 & 6 

– “Non-DHCP 

Connection” and “IP Reset Button/Reset Mini Control Network Settings”

 

(3)

 

Perform a Mini 

device Firmware Update as described in

 #15 on Page 10 

and

 (4) 

As recommended, use a 

DHCP enabled network connection for all devices using a router/POE switch combination 
whenever you can to eliminate connection issues.  
 

 

Those connection solutions resolve 99% of any Yellow indicator connection issues but to 
assist further if connection issues persist - when the indicator is Yellow you can hover your 
cursor over the device and there is a pop-up Tooltip message to tell you the kind of issues it 
has detected.   
A few message and solution examples include,  
 

Message

: Device not ready.  

Solution

: Wait a minute or two till the device is ready and it should then connect and the  

indicator turn Green.  

Solution

: If the indicator remains Yellow, close the NeuConsole software and then re-open.  

Or Reset the processor.  

Message

: Device Schematic Not ready.  

Solution

: The processor has already been loaded with a DSP design. Give the connection  

process a minute to connect and if it does not connect close the NeuConsole  
software, open it again, select Start Network View and you should now see that 
the processor is connected and operational - as indicated by the Green network  
connection indicator to the left of the processor device model.  

Message

: DSP Processing Error.  

Solution

: This could be a bad DSP Design schematic. You may need to reload the DSP  

schematic and restart and/or restart device to reset its DSP chip.  

Message

: Error in Firmware Upgrade.  

Solution

: It will print out an error code when you hover your cursor over the device in  

Network View (Do Firmware Upgrade again). 
 
 

 

       13.

 

Manual Assignment of Static IP Addresses to Multiple Devices 

– No DHCP:                                           

   

Each Mini device indirectly connected to the PC via a network switch.                                          
Unique, manually assigned/static IP addresses are assigned to each Mini device prior to being 
installed.  

Make sure your computer is set to “Obtain IP Address Automatically”.

                               

We will set your computer’s static IP Address after changing the IP Addresses on all the 
Mini devices first. 

Summary of Contents for Mini Series

Page 1: ...are programmed to control the processors using a drag drop configuration software from within the NeuConsole software available at www xilica com External power supply included but we recommend you po...

Page 2: ...e plug has two blades and a third grounding prong The wide blade or the third prongs are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacem...

Page 3: ...net cable using a POE router switch or router switch combo recommended An external power supply is also included with each Mini wall control All Mini Series wall control models have an aluminum front...

Page 4: ...rop configuration form within the processors NeuConsole software 4 Label Slot Place supplied or unique label in label slot and cover with included protective plastic cover 5 Programmable Level Control...

Page 5: ...a POE switch This combo will provide DHCP as well as power to the Mini wall controls over their Ethernet cable s by way of the switches POE feature Power Over Ethernet Linksys routers NetGear switches...

Page 6: ...7 Mini Series Wall Control and Processor Devices Connected and Powered Up Before getting started make sure that your NeuConsole Software and processor Firmware are compatible up to date See software...

Page 7: ...Neutrino model would be shown connected Network View as shown above displays all devices connected to the network plus information such as the device model a green yellow or red network connection in...

Page 8: ...n the indicator is Yellow you can hover your cursor over the device and there is a pop up Tooltip message to tell you the kind of issues it has detected A few message and solution examples include Mes...

Page 9: ...hey can be installed and we will also assign a manual static IP address to your PC as instructed in 14 below 14 A Static IP Address for your Computer Multiple Devices No DHCP In this section we will b...

Page 10: ...le software are connected and operational and before you start programming the Mini device make sure it s Firmware is compatible with the software Check device firmware version in Network View See www...

Page 11: ...t we want controlled by the Mini wall control Note We will program a Mini S4K1 control but the opened module image shown is that of the similar looking Mini K4 The exact Mini S4K1 image was not availa...

Page 12: ...Mini S4K1 model placed in the project view work area and the U0808 processor module is a light see through red and grey color as shown below Map Physical Device With the Mini control module for this c...

Page 13: ...isplay the DSP design schematic and DSP modules saved within it as shown below Next double click the red Mini S4K1 control module to open it and display the Mini control device The Mini S4K1 on off bu...

Page 14: ...t in Yellow to Capture the entire parameter function as shown at right Release once highlighted Once highlighted properly the parameter function will change colour and have an orange highlight line ar...

Page 15: ...ht red in color to indicate that they have been programmed and the Mini wall controls 3 remaining On Off buttons remain light green in color as indicated ready to be programmed with other Switch and P...

Page 16: ...work area page as shown below This button selection actually performs two functions at the same time it transfers or saves your Mini programming and DSP design to the connected physical Mini control d...

Page 17: ...ain white background Note the added green Mute All Devices button at the top of the Online Mode page between the System Presets button and the Zoom control Note that when visible or when you collapse...

Page 18: ...gn project in the early stages of a DSP design using our Neutrino processor or in conjunction with our Uno processor after downloading an Uno App both starting from scratch using New Design Project or...

Reviews: