Xilica Audio Design Mini Series Quick Start Manual Download Page 10

               

NeuPanel-Mini Series 

Quick Start Guide

 

 
 

XILICA AUDIO DESIGN CANADA / ASIA / EUROPE 

 

Page | 10 

 

Note

:

  Each Mini device (and processor device) also has a software based Remote Reset 

function to augment its physical IP Reset switch but the physical IP Reset procedure is more 
reliable. 
If you have already installed Mini controls and need to do an IP Reset, try using the software 
Remote Reset procedure first before removing it from the wall to do a physical Reset.   

To accomplish a software Remote Reset, 

Right click the Mini device (or processor device) in 

Network View

 and select 

Remote Reset

 

 

15.  Firmware Upgrade to Mini Series Wall Control Device: 

Once the Mini devices and the NeuConsole software are connected and operational and before 
you start programming the Mini device - make 

sure it’s 

Firmware

 is compatible with the software. 

Check device firmware version in Network View. See 

www.xilica.com

 

– verify, download latest 

firmware, save file to your PC 

– and proceed below if you need to upgrade the Mini’s firmware. 

 

 

Power must not be disrupted during a firmware upgrade procedure 

 

In Network View

 

– Right click the Mini device, Select “

Firmware Upgrade

” from the menu 

and follow the instructions to install your saved firmware update as shown below. 

 

Note:

  As indicated with a safety message during the firmware upgrade procedure 

– a 

firmware upgrade will erase all saved data on the device.  Thus perform this procedure 
before you program your Mini control device (or re-transfer/save a saved project design file to 
the Mini device after the firmware upgrade is complete). 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Mini Series

Page 1: ...are programmed to control the processors using a drag drop configuration software from within the NeuConsole software available at www xilica com External power supply included but we recommend you po...

Page 2: ...e plug has two blades and a third grounding prong The wide blade or the third prongs are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacem...

Page 3: ...net cable using a POE router switch or router switch combo recommended An external power supply is also included with each Mini wall control All Mini Series wall control models have an aluminum front...

Page 4: ...rop configuration form within the processors NeuConsole software 4 Label Slot Place supplied or unique label in label slot and cover with included protective plastic cover 5 Programmable Level Control...

Page 5: ...a POE switch This combo will provide DHCP as well as power to the Mini wall controls over their Ethernet cable s by way of the switches POE feature Power Over Ethernet Linksys routers NetGear switches...

Page 6: ...7 Mini Series Wall Control and Processor Devices Connected and Powered Up Before getting started make sure that your NeuConsole Software and processor Firmware are compatible up to date See software...

Page 7: ...Neutrino model would be shown connected Network View as shown above displays all devices connected to the network plus information such as the device model a green yellow or red network connection in...

Page 8: ...n the indicator is Yellow you can hover your cursor over the device and there is a pop up Tooltip message to tell you the kind of issues it has detected A few message and solution examples include Mes...

Page 9: ...hey can be installed and we will also assign a manual static IP address to your PC as instructed in 14 below 14 A Static IP Address for your Computer Multiple Devices No DHCP In this section we will b...

Page 10: ...le software are connected and operational and before you start programming the Mini device make sure it s Firmware is compatible with the software Check device firmware version in Network View See www...

Page 11: ...t we want controlled by the Mini wall control Note We will program a Mini S4K1 control but the opened module image shown is that of the similar looking Mini K4 The exact Mini S4K1 image was not availa...

Page 12: ...Mini S4K1 model placed in the project view work area and the U0808 processor module is a light see through red and grey color as shown below Map Physical Device With the Mini control module for this c...

Page 13: ...isplay the DSP design schematic and DSP modules saved within it as shown below Next double click the red Mini S4K1 control module to open it and display the Mini control device The Mini S4K1 on off bu...

Page 14: ...t in Yellow to Capture the entire parameter function as shown at right Release once highlighted Once highlighted properly the parameter function will change colour and have an orange highlight line ar...

Page 15: ...ht red in color to indicate that they have been programmed and the Mini wall controls 3 remaining On Off buttons remain light green in color as indicated ready to be programmed with other Switch and P...

Page 16: ...work area page as shown below This button selection actually performs two functions at the same time it transfers or saves your Mini programming and DSP design to the connected physical Mini control d...

Page 17: ...ain white background Note the added green Mute All Devices button at the top of the Online Mode page between the System Presets button and the Zoom control Note that when visible or when you collapse...

Page 18: ...gn project in the early stages of a DSP design using our Neutrino processor or in conjunction with our Uno processor after downloading an Uno App both starting from scratch using New Design Project or...

Reviews: