Advanced Function
Support Read/Write gearbox special EEPROM. Support set unit status while write data.
That means you can renew gearbox without erase password
1.
Read:
Read module special EEPROM.
2.
Save File
…
: Save the read EEPROM file.
3.
Load File
…
: Load the saved EEPROM file.
4.
Write
: Write EEPROM to unit
,
it will set the selected status to module.
5.
Set unit status
: Set unit status, you can set status to unit by write once.
Set Activated: Will set Initialized, TP Cleared, Personalized, Activated status.
Set Personalized: Will set Initialized, TP Cleared, and Personalized status; not set
Activated status.
Set TP Cleared: Will set Initialized, TP Cleared status; not set Personalized,
Activated status.
Set Initialized: Will set Initialized status; not set Cleared, Personalized, Activated
status.