5 Hardware Description
2022-08-12
28
Table 5-6
M.2 FRU indicator description
Indicator
Description
M.2 FRU fault indicator
⚫
Off: The M.2 FRU is running properly.
⚫
Blinking yellow: The M.2 FRU is being located, or RAID
is being rebuilt.
⚫
Steady yellow: The M.2 FRU is faulty or not detected.
M.2 FRU activity
indicator
⚫
Off: The M.2 FRU is not in position or is faulty.
⚫
Blinking green: Data is being read, written, or
synchronized.
⚫
Steady green: The M.2 FRU is inactive.
NVMe Drive Indicators
Figure 5-14
NVMe drive indicators
⚫
If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives
support surprise hot swap.
Table 5-7
NVMe drive indicators (VMD enabled)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive cannot be detected.
Steady on
Off
The NVMe drive is working properly.
Blinking at 2 Hz
Off
Data is being read from or written to the
NVMe SSD.
Off
Blinking at 2 Hz
The NVMe drive is being located.
Steady on/Off
Steady on
The NVMe drive is faulty.
⚫
If the VMD function is disabled, NVMe drives support only orderly hot swap.