Configuratio
n
Maximum
Operating
Temperature
30
℃
(86°F)
Maximum
Operating
Temperature
35ºC (95°F)
Maximum
Operating
Temperature
40ºC (104°F)
Maximum
Operating
Temperature
45ºC (113°F)
than 185
W
c
.
a: CPU models with TDP that equals to or is lower than 270 W: 8454H/8450H/
8444H/6434H/6448H/6418H/6416H
b: CPU models with TDP that is greater than 270 W: 8490H/8468H/8460H
c: CPU models with TDP that equals to or is lower than 185 W: 6418H/6416H
NO TE
● When a single fan is faulty, the highest operating temperature is 5°C (9°F) lower than the
rated value.
● It is recommended that the GPU A2 cards be configured in the sequence of slot 1 > slot 7 >
slot 2 > slot 8 > slot 3 > slot 9.
● It is recommended that servers be deployed at an interval of 1U to reduce server noise and
improve server energy efficiency.
A.4 Nameplate
Certified Model
Remarks
H24H-07
Global
A.5 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can configure these features for better performance.
For details about RAS features, see the
FusionServer Sapphire Rapids Platform
Server RAS Feature Technical White Paper
.
A.6 Sensor List
Sensor
Description
Component
Inlet Temp
Air inlet temperature
Right mounting ear
Mngmnt Health
Management subsystem
health status
Management module
Outlet Temp
Air outlet temperature
BMC card
FusionServer 2488H V7 Server
Technical White Paper
A Appendix
Issue 01 (2023-09-01)
Copyright © xFusion Digital Technologies Co., Ltd.
81