Silkscr
een
Indicator/
Button
Description
UID button/
indicator
The UID button/indicator helps identify and locate a
device.
UID indicator:
● Off: The device is not being located.
● Blinking or steady blue: The device is being
located.
UID button:
● You can control the UID indicator status by pressing
the UID button or using the iBMC.
● You can press this button to turn on or off the UID
indicator.
● You can press and hold down this button for 4 to 6
seconds to reset the iBMC.
Health status
indicator
● Off: The device is powered off or faulty.
● Blinking red at 1 Hz: A major alarm has been
generated on the system.
● Blinking red at 5 Hz: A critical alarm has been
generated on the system.
● Steady green: The device is operating properly.
FlexIO card
presence
indicator
● Off: The FlexIO card is not detected.
● Blinking green at 0.5 Hz: The FlexIO card is
detected but is not powered on.
● Blinking green at 2 Hz: The FlexIO card is detected
and has just been inserted.
● Steady green: The FlexIO card is detected and the
power supply is normal.
iBMC direct
connect
management
port indicator
Indicates the status when the iBMC direct connect
management port connects to a terminal (local PC):
● Off: No terminal is connected.
● Blinking green at short intervals for 3 seconds and
then off: The port is disabled.
● Steady green: The terminal is connected.
5.1.3 Ports
Port Positions
●
8 x 2.5" drive pass-through configuration (8 x SAS/SATA)
FusionServer 2488H V7 Server
Technical White Paper
5 Hardware Description
Issue 01 (2023-09-01)
Copyright © xFusion Digital Technologies Co., Ltd.
13