background image

FusionServer 2488H V6 Server 
Technical White Paper 

5 Hardware Description 

 

2022-08-12 

39 

 

CPU 

Memory Channel 

Memory Slot 

CPU 1 

A (primary) 

DIMM000(A) 

DIMM001(G) 

B (primary) 

DIMM010(B) 

DIMM011(H) 

C (primary) 

DIMM020(C) 

DIMM021(I) 

D (primary) 

DIMM030(D) 

DIMM031(J) 

E (primary) 

DIMM040(E) 

DIMM041(K) 

F (primary) 

DIMM050(F) 

DIMM051(L) 

CPU 2 

A (primary) 

DIMM100(A) 

DIMM101(G) 

B (primary) 

DIMM110(B) 

DIMM111(H) 

C (primary) 

DIMM120(C) 

DIMM121(I) 

D (primary) 

DIMM130(D) 

DIMM131(J) 

E (primary) 

DIMM140(E) 

DIMM141(K) 

F (primary) 

DIMM150(F) 

DIMM151(L) 

CPU 3 

A (primary) 

DIMM200(A) 

DIMM201(G) 

B (primary) 

DIMM210(B) 

DIMM211(H) 

C (primary) 

DIMM220(C) 

DIMM221(I) 

D (primary) 

DIMM230(D) 

Summary of Contents for FusionServer 2488H V6

Page 1: ...FusionServer 2488H V6 Server Technical White Paper Issue 04 Date 2022 08 12 xFusion Digital Technologies Co Ltd...

Page 2: ...bear any liability resulting from the use of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products serv...

Page 3: ...rts 26 5 3 Processors 28 5 4 Memory 28 5 4 1 DDR4 Memory 28 5 4 1 1 Memory Identifier 28 5 4 1 2 Memory Subsystem Architecture 29 5 4 1 3 Memory Compatibility 31 5 4 1 4 Memory Installation Guidelines...

Page 4: ...1 5 7 3 PCIe Slot Description 64 5 8 PSUs 65 5 9 Fan Modules 66 5 10 LCD 67 5 11 Boards 70 5 11 1 Mainboard 70 5 11 2 Drive Backplane 72 5 11 3 PSU Backplane 75 6 Product Specifications 76 6 1 Technic...

Page 5: ...el of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard wi...

Page 6: ...3 2022 06 25 Added a figure that shows how to measure dimensions Added A 1 Chassis Label Upgrades the standards of CE UKCA and CCC certifications in the chapter 10 Certifications 02 2022 03 18 Added 1...

Page 7: ...s ideal for applications such as databases cloud computing virtualization in memory computing and deep learning The secure compact 2488H V6 is a highly expandable server delivering high performance co...

Page 8: ...l computation capability The hardware assisted Intel Virtualization Technology Intel VT allows operating system OS to better use hardware to address virtualization workloads Intel Deep Learning Boost...

Page 9: ...and availability The server supports hot swappable SAS SATA NVMe drives SAS SATA drives support RAID 0 1 10 5 50 6 and 60 depending on the RAID controller card used It also uses a supercapacitor to pr...

Page 10: ...g configuration Configuring any port on the OCP 3 0 network adapter or other network adapters that support the NC SI feature as the service port with NC SI enabled Enabling disabling and setting a vir...

Page 11: ...Technical White Paper 3 Physical Structure 2022 08 12 11 3 Physical Structure Figure 3 1 Physical structure of a server with 8 x 2 5 drives example 1 PCIe riser module 1 2 PCIe card 3 PCIe riser modu...

Page 12: ...M 2 SSDc 21 Mainboard 22 OCP 3 0 Network Adapters 23 DIMM a The server supports only PCIe RAID controller cards which can be configured with a supercapacitor For details about the slots for installin...

Page 13: ...s processors interconnect with each other through six UPI links at a speed of up to 10 4 GT s The server supports a maximum of 11 PCIe 3 0 expansion slots including one slot dedicated for the OCP 3 0...

Page 14: ...on 2022 08 12 14 5 Hardware Description 5 1 Front Panel 5 2 Rear Panel 5 3 Processors 5 4 Memory 5 5 Storage 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fan Modules 5 10 LCD 5 11 Boards 5 1 Front Panel...

Page 15: ...SATA drive 2 Optional Built in DVD drive or LCD module 3 Slide out label plate with an SN label 12 x 2 5 drive pass through configuration 4 x SAS SATA 8 x NVMe Figure 5 2 Front view 1 SAS SATA drive 2...

Page 16: ...ller panel in drive slot NOTE The slot cannot hold drives 4 Slide out label plate with an SN label 24 x 2 5 drive pass through configuration 24 x SAS SATA Figure 5 4 Front view 1 SAS SATA drive 2 Fill...

Page 17: ...x 2 5 drive pass through configuration 8 x SAS SATA Figure 5 6 Indicators and buttons on the front panel 1 Fault diagnosis LED 2 Power button indicator 3 Health status indicator 4 UID button indicator...

Page 18: ...ators and buttons on the front panel 1 Fault diagnosis LED 2 Power button indicator 3 Health status indicator 4 UID button indicator 5 FlexIO card presence indicator 6 iBMC direct connect management p...

Page 19: ...ails about error codes see the FusionServer Rack Server iBMC Alarm Handling Power button indicator Power indicator Off The device is not powered on Steady green The device is powered on Blinking yello...

Page 20: ...button or using the iBMC You can press this button to turn on or off the UID indicator You can press and hold down this button for 4 to 6 seconds to reset the iBMC FlexIO card presence indicator Off T...

Page 21: ...ct management port 3 VGA port 12 x 2 5 drive pass through configuration 4 x SAS SATA 8 x NVMe Figure 5 12 Ports on the front panel 1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port 20 x...

Page 22: ...5 drive EXP configuration 25 x SAS SATA Figure 5 15 Ports on the front panel 1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port Port Description Table 5 2 Ports on the front panel Port T...

Page 23: ...t USB 3 0 2 Used to connect to a USB 3 0 device NOTICE Before connecting an external USB device ensure that the USB device functions properly Otherwise it may adversely impact the server The USB 3 0 p...

Page 24: ...k adapter see 5 6 1 OCP 3 0 Network Adapter The figure is for reference only The actual configuration may vary 5 2 2 Indicators and Buttons Indicator Positions Figure 5 17 Indicators on the rear panel...

Page 25: ...e network port is connected properly Health status indicator Off The device is powered off or is faulty Blinking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A criti...

Page 26: ...excluding failure of all devices Table 5 4 FlexIO card power indicator and status indicator FlexIO Card Power Indicator Green FlexIO Card Status Indicator Yellow Description Off Off The FlexIO card i...

Page 27: ...command NOTE The port uses 3 wire serial communication interface and the default baud rate is 115 200 bit s VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB 3 0 port USB...

Page 28: ...ssors If two processors are required install them in sockets CPU1 and CPU2 Processors of the same model must be used in a server Contact your local sales representative or see Search Parts in the Comp...

Page 29: ...it 4 Type of the memory interface PC4 DDR4 5 Maximum memory speed 2933 MT s 3200 MT s 6 Memory latency parameters CL tRCD tRP W 20 20 20 Y 21 21 21 AA 22 22 22 7 DIMM type R RDIMM L LRDIMM 5 4 1 2 Mem...

Page 30: ...ary DIMM020 C C DIMM021 I D primary DIMM030 D D DIMM031 J E primary DIMM040 E E DIMM041 K F primary DIMM050 F F DIMM051 L CPU 2 A primary DIMM100 A A DIMM101 G B primary DIMM110 B B DIMM111 H C primar...

Page 31: ...primary DIMM240 E E DIMM241 K F primary DIMM250 F F DIMM251 L CPU 4 A primary DIMM300 A A DIMM301 G B primary DIMM310 B B DIMM311 H C primary DIMM320 C C DIMM321 I D primary DIMM330 D D DIMM331 J E pr...

Page 32: ...pacity of all DDR4 memory modules The total memory capacity cannot exceed the maximum memory capacity supported by the CPUs For details about the capacity type of a single memory module see Search Par...

Page 33: ...mory Installation Guidelines Observe the following when configuring DDR4 memory modules Install memory modules only when corresponding processors are installed Do not install LRDIMMs and RDIMMs in the...

Page 34: ...les To maximize performance balance the total memory capacity between the installed processors and to load the channels similarly whenever possible Observe the memory module installation rules when co...

Page 35: ...FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 2022 08 12 35 Figure 5 21 Memory slots...

Page 36: ...5 23 DDR4 memory installation guidelines 4 processors 5 4 1 6 Memory Protection Technologies The following memory protection technologies are supported ECC Memory Mirroring Memory Single Device Data C...

Page 37: ...ction Technologies The following memory protection technologies are supported ECC Memory Mirroring Memory Single Device Data Correction SDDC Failed DIMM Isolation Memory Thermal Throttling Command Add...

Page 38: ...1XXD512GPSU4 4 Capacity GB 128 256 512 5 SN QR code 8089 A2 2008 00002461 5 4 2 2 Memory Subsystem Architecture The server provides 48 memory slots Each processor integrates six memory channels and ea...

Page 39: ...I D primary DIMM030 D D DIMM031 J E primary DIMM040 E E DIMM041 K F primary DIMM050 F F DIMM051 L CPU 2 A primary DIMM100 A A DIMM101 G B primary DIMM110 B B DIMM111 H C primary DIMM120 C C DIMM121 I...

Page 40: ...e the following rules when configuring PMem modules The PMem modules must be used with the DDR4 memory modules For details see FusionServer PMem 200 User Guide Contact your local sales representative...

Page 41: ...6 2666 a The maximum number of PMem modules is based on four processor configuration The value is halved for a server with two processors b The maximum PMem capacity varies depending on the CPU type a...

Page 42: ...GB DDR4 6 x 128 GB PMem Cooper Lake HL series 4 5 TB 6 x 256 GB DDR4 6 x 512 GB PMem Note For details about the configurable memory capacity see Search Parts in the Compatibility Checker 5 4 2 5 Memor...

Page 43: ...FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 2022 08 12 43 Figure 5 25 Memory slots...

Page 44: ...FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 2022 08 12 44 Figure 5 26 PMem installation guidelines 2 processors...

Page 45: ...ssor 5 4 2 6 Memory Protection Technologies The following memory protection technologies are supported PMem module Error Detection and Correction PMem module Device Failure Recovery SDDC PMem module P...

Page 46: ...ive configuration Configuration Front Drive Rear Drive Built in Drive Drive Management Mode 8 x 2 5 drive pass through configuration 8 x SAS SATA Front drive 8 x 2 5 Slots 0 to 7 support only SAS SATA...

Page 47: ...anages the M 2 SSDs on the Avago SAS300 4iMR PCIe RAID controlle r card in slot 1 12 x 2 5 drive pass through configuration 4 x SAS SATA 8 x NVMe Front drive 12 x 2 5 Slots 0 to 3 support only SAS SAT...

Page 48: ...SAS300 4iMR PCIe RAID controlle r card in slot 1 20 x 2 5 drive pass through configuration 4 x SAS SATA 16 x NVMe Front drive 20 x 2 5 Slots 0 to 3 support only SAS SAT A drives Slots 4 to 11 and slo...

Page 49: ...RAID controlle r card in slot 1 24 x 2 5 drive pass through configuration 24 x SAS SATA Front drive 24 x 2 5 Slots 0 to 23 support only SAS SATA drives 2 x M 2 SSDs The Avago SAS3004iM R RAID controll...

Page 50: ...ment Mode 7 The PCIe RAID controlle r card in slot 5 manages the drives in slots 16 to 23 M 2 SSD PCH passthro ugh Manages the M 2 SSDs on the M 2 SSD adapter card in slot 10 Intel VROC SATA RAID Mana...

Page 51: ...drives 2 x M 2 SSDs The Avago SAS3004iM R RAID controller card in slot 1 supports M 2 SSDs 2 x M 2 SSDs The M 2 SSD adapter card in slot 10 supports M 2 SSDs SAS SATA drive 1 x PCIe RAID controlle r...

Page 52: ...ts to be used 5 5 2 Drive Numbering The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card The drive numbers identified by the RAID controll...

Page 53: ...ontroller 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 12 x 2 5 drive pass through configuration 4 x SAS SATA 8 x NVMe Figure 5 29 Slot numbers Table 5 13 Slot numbers Drive No Drive Number Identified by the iBMC Dr...

Page 54: ...30 Slot numbers Table 5 14 Slot numbers Drive No Drive Number Identified by the iBMC Drive Number Identified by the RAID Controller 0 0 0 1 1 1 2 2 2 3 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 16 16 1...

Page 55: ...Slot numbers Table 5 15 Slot numbers Drive No Drive Number Identified by the iBMC Drive Number Identified by the RAID Controller 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 0 9 9 1 10 10 2 11...

Page 56: ...ion 25 x SAS SATA Figure 5 32 Slot numbers Table 5 16 Slot numbers Drive No Drive Number Identified by the iBMC Drive Number Identified by the RAID Controller 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6...

Page 57: ...rs Table 5 17 SAS SATA drive indicators Activity Indicator Green Fault Indicator Yellow Description Off Off The drive is not in position Steady on Off The drive is detected Blinking at 4 Hz Off Data i...

Page 58: ...ng at 2 Hz Off Data is being read from or written to the NVMe drive Off Blinking at 2 Hz The NVMe drive is being located Off Blinking at 8 Hz The data on the secondary NVMe drive is being rebuilt Stea...

Page 59: ...igure 5 35 M 2 FRU indicators Table 5 20 M 2 FRU indicators M 2 FRU Active Indicator Green M 2 FRU Fault Indicator Yellow Description Off Off The M 2 FRU is not detected Steady on Off The M 2 FRU is i...

Page 60: ...t your local sales representative or see Search Parts in the Compatibility Checker to determine the components to be used For details about the OCP 3 0 network adapter see the documents of each OCP 3...

Page 61: ...slot PCIe riser module is used slot 3 is unavailable PCIe riser module 2 provides slots 7 8 and 9 If a dual slot PCIe riser module is used slot 9 is unavailable The mainboard provides slots 4 5 6 and...

Page 62: ...n installed in PCIe riser module 1 Provides PCIe slots 7 and 8 when installed in PCIe riser module 2 Figure 5 38 PCIe riser module universal 2 slot PCIe riser module universal 3 slot supporting GPUs P...

Page 63: ...ot supporting GPUs PCIe riser module universal 2 slot supporting GPUs Provides PCIe slots 1 and 2 when installed in PCIe riser module 1 Provides PCIe slots 7 and 8 when installed in PCIe riser module...

Page 64: ...ations Slot 1 CPU 1 PCIe 3 0 x16 x8 Port2A 0x23 0 0 0x24 0 0 FHFL Slot 2 CPU 1 PCIe 3 0 x16 x16 Port4A 0x32 0 0 0x33 0 0 FHFL Slot 3 CPU 4 PCIe 3 0 x16 2 sl ot PCI e riser mod ule PR M N A 3 sl ot PR...

Page 65: ...PCIe slot width cannot be smaller than the PCIe card link width The full height full length FHFL PCIe slots are compatible with FHFL PCIe cards full height half length FHHL PCIe cards and half height...

Page 66: ...0 W When one or two 3000 W AC Titanium PSUs are configured If the input voltage ranges from 100 V AC to 127 V AC the output power decreases to 1300 W If the input voltage ranges from 200 V AC to 220 V...

Page 67: ...figuration 8 x SAS SATA supports the LCD Function The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management networ...

Page 68: ...e 5 43 LCD subsystem working principle UI Figure 5 44 LCD main interface Table 5 22 Parameters on the LCD home screen Tab Function Status Displays the port 80 status serial number component status and...

Page 69: ...erature of the server Info Displays the IP address and MAC address of the iBMC management network port device SNs asset information and firmware version Setting Sets the IP address of the iBMC managem...

Page 70: ...2022 08 12 70 5 11 Boards 5 11 1 Mainboard Figure 5 45 2488H V6 mainboard 1 Rear USB 3 0 port USB3 0x2 J80 2 VGA port VGA CONN J14 3 Serial port IO IO J148 4 BMC management network port BMC Mesg J149...

Page 71: ...tor 6 FAN6 POD6 J2007 25 6076 fan module connector 5 FAN5 J11 26 6038 fan module connector 5 FAN5 POD5 J2006 27 6076 fan module connector 4 FAN4 J8 28 6038 fan module connector 4 FAN4 POD4 J2005 29 60...

Page 72: ...50 PCIe riser 2 slot PCIE RISER2 CPU2 J88 a Reserved and unavailable currently 5 11 2 Drive Backplane Front Drive Backplane 8 x 2 5 drive pass through backplane 8 x SAS SATA Figure 5 46 8 x 2 5 drive...

Page 73: ...e 3 connector SLIM_3 J1101 5 Power connector HDD POWER J4003 6 Backplane signal cable connector HDD_BP J3702 7 Mini SAS HD Port A connector PORTA J801 20 x 2 5 drive pass through backplane 4 x SAS SAT...

Page 74: ...ower2 J7303 15 14 pin power connector for the drive backplane HDD_Power1 J30 16 Signal connector for the drive backplane HDD_BP J7102 24 x 2 5 drive pass through backplane 24 x SAS SATA Figure 5 49 24...

Page 75: ...D Port B connector PORTB J29 4 Mini SAS HD Rear Port connector REAR PORT J31 a 5 Signal connector for the drive backplane HDD_BP J1 6 Power connector for the drive backplane POWER J24 7 Signal connect...

Page 76: ...or four processors Third generation Intel Xeon Scalable Cooper Lake processors Built in memory controller and six memory channels per processor Built in PCIe controller supporting PCIe 3 0 and 48 lan...

Page 77: ...ve configurations For details see 5 5 1 Drive Configurations Supports M 2 SSDs M 2 SSDs are supported for RAID configuration when the server is configured with an Avago SAS3004iMR RAID controller card...

Page 78: ...ensure user data security The PCIe RAID controller card occupies one PCIe slot For details about the RAID controller card see V6 Server RAID Controller Card User Guide NOTE If the BIOS is in legacy m...

Page 79: ...ion 1920 x 1200 only after the video card driver matching the operating system version is installed Otherwise only the default resolution supported by the operating system is provided If both the fron...

Page 80: ...creases by 1 C 1 8 F for every increase of 300 m 984 24 ft When the server configuration complies with ASHRAE Class A3 and the altitude is above 900 m 2952 76 ft the highest operating temperature decr...

Page 81: ...be lost or faults may occur if the preservation duration exceeds the specified maximum duration When drives are preserved under the storage temperature and humidity specified in the preceding table th...

Page 82: ...company s cabinets Static rail kit applies to cabinets with a distance of 543 5 mm to 848 5 mm 21 40 in to 33 41 in between the front and rear mounting bars Ball bearing rail kit applies to cabinets...

Page 83: ...6 Product Specifications 2022 08 12 83 Item Description Energy consumption The power consumption parameters vary with hardware configurations including the configurations complying with EU ErP Use th...

Page 84: ...middleware software and hardware The slight differences of the application software middleware basic software and hardware may cause performance inconsistency between the application layer and test s...

Page 85: ...to perform special tasks such as performing high voltage operations and driving a forklift If this device works in a residential environment the wireless interference may be generated Personal Safety...

Page 86: ...tches and jewelry Figure 8 2 shows conductive objects that must be removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Put your h...

Page 87: ...or dedicated servers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device...

Page 88: ...ith local regulations for the maximum load per person Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried pe...

Page 89: ...able running of the device The iBMC allows screenshots and videos to be created when the system breaks down facilitating cause analysis of the system breakdown The iBMC offers screen snapshots and vid...

Page 90: ...nchronizes network time to optimize time configuration The iBMC supports domain name system DNS and Lightweight Directory Application Protocol LDAP to implement domain management and directory service...

Page 91: ...A11 2020 CISPR 32 2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI...

Page 92: ...55024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 RoHS BS EN IEC 63000 2018 ErP Commission Regulation EU 424 2019 US FCC FCC PART 15 Canada IC ICES 003...

Page 93: ...n are for reference only For details see the actual product A 1 1 On the Front Top Figure A 1 Chassis head label 1 Nameplate 2 Certificate 3 Quick access tag 4 SN NOTE For details see A 2 Product SN 5...

Page 94: ...1 1 1 Nameplate Figure A 2 Nameplate example Table A 1 Nameplate description No Description 1 Server Model For details see A 4 Nameplate 2 Device names 3 Power Supply Requirements 4 Vendor Information...

Page 95: ...scription No Description 1 P fixed 2 Z fixed 3 Y Server B Semi finished product of the whole machine N Loose spare parts 4 0 Reserved bit 5 Year 2 digits 6 Month 1 digit Digits 1 to 9 indicate January...

Page 96: ...turing serial number 5 digits A 1 1 3 Sample Quick Access Tags Figure A 5 Sample quick access tags Table A 4 Quick access tab description No Description 1 IP address of the iBMC management network por...

Page 97: ...guide is located on the inside of the chassis cover It describes how to remove the mainboard components important components of the chassis precautions and QR codes of technical resources The picture...

Page 98: ...from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1 0 and 2 The second character indicates the month Digits 1 to 9 indicate Janua...

Page 99: ...0 network adapters are not supported 100GE PCIe NICs are not supported 100GE IB cards are not supported per processor are supported Up to twenty four 64 GB DDR4 memory modules are supported Up to two...

Page 100: ...6H model processor GPU cards are not supported Up to 205 W processor is supported Except for the 8356H model processor 100GE OCP 3 0 network adapters are supportedc 100GE PCIe NICs are supportedc 100G...

Page 101: ...wo full length GPU cards or four half length GPU cards the server supports processors with up to 165 W TDP per processor b Full length GPU cards are not supported When configured with two half length...

Page 102: ...sition U240 on the mainboard CPUN Core Rem CPU core temperature CPU N indicates the CPU number The value ranges from 1 to 4 CPUN DTS Difference between the real time CPU temperature and the core CPU t...

Page 103: ...m 1 to 6 FANN R Speed Power Server input power Total PSU power PowerN PSU input power PSU N indicates the PSU number The value is 1 or 2 CPUN Status CPU status CPU N indicates the CPU number The value...

Page 104: ...tes the DIMM slot number PCH Status PCH chip fault diagnosis health status Component in position U240 on the mainboard LCD Presence LCD presence LCD LCD Status LCD health status PS Redundancy Redundan...

Page 105: ...ction for soft start riser 1 slots 4 5 6 SYS 12V_7 Mainboard 12 0 V voltage the seventh output 12 V voltage detection for soft start riser 2 VCC_3V3 USB_VCC_5V SYS 12V_8 Mainboard 12 0 V voltage the e...

Page 106: ...or PwrOn TimeOut Power on timeout PwrCap Status Power capping status NIC1 Presence NIC 1 presence HDD Backplane Drive backplane entity presence HDD BP Status Drive backplane health status PortN Link D...

Page 107: ...me Hopping Time hopping NTP Sync Failed NTP synchronization failure and recovery events Host Loss System monitoring software BMA link loss detection GPUN Temp GPU temperature PCIeN Inlet Temp PCIe sma...

Page 108: ...anage the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Co...

Page 109: ...ing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI system...

Page 110: ...tored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet chass...

Page 111: ...urrent AES Advanced Encryption Standard New Instruction Set ARP Address Resolution Protocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard manage...

Page 112: ...memory DVD digital video disc E ECC error checking and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS E...

Page 113: ...ent controller IC Industry Canada ICMP Internet Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers I...

Page 114: ...edia access control MMC module management controller N NBD next business day NC SI Network Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect Exp...

Page 115: ...ial Advanced Technology Attachment SCM supply chain management SDDC single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management...

Page 116: ...DIMM unbuffered dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bus...