![xFusion Digital Technologies FusionServer 2488H V6 Technical Manual Download Page 27](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-2488h-v6/fusionserver-2488h-v6_technical-manual_3321015027.webp)
FusionServer 2488H V6 Server
Technical White Paper
5 Hardware Description
2022-08-12
27
3
VGA port
4
USB 3.0 ports
5
Socket for PSU 1
6
Socket for PSU 2
Port Description
Table 5-5
Ports on the rear panel
Port
Type
Quantity
Description
Management
network port
RJ45
1
iBMC management network port,
which is used to manage the
server.
NOTE
The management network port is a
GE port that supports 100 Mbit/s and
1000 Mbit/s auto-negotiation.
Serial port
RJ45
1
Default operating system serial
port used for debugging. You can
also set it as the iBMC serial port
by using the iBMC command.
NOTE
The port uses 3-wire serial
communication interface, and the
default baud rate is 115,200 bit/s.
VGA port
DB15
1
Used to connect a display
terminal, such as a monitor or
KVM.
USB 3.0 port
USB 3.0
2
Used to connect to a USB 3.0
device.
NOTICE
⚫
Before connecting an external
USB device, ensure that the USB
device functions properly.
Otherwise, it may adversely
impact the server.
⚫
The USB 3.0 port can be used to
supply power to low-power
peripherals. However, the USB
3.0 port must comply with the
USB specifications. To run
advanced peripherals, such as
external CD/DVD drives, an
external power supply is required.
PSU socket
-
2
Used to connect to a power
distribution unit (PDU) through a
power cable. You can select the
PSUs as required.
NOTE
When determining the PSUs, ensure