FusionServer 2488H V5 Server
Technical White Paper
5 Hardware Description
Issue 07 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
44
Table 5-15
LOM description
NI
C
Ty
pe
Chip Model Port
Type
Numb
er of
Ports
Rate
Negotiation
Mode
Supported
Rates
Rates Not
Supported
LO
Ms
X722
10GE
optical
port
2
Auto-negotia
tion 10,000
Mbit/s (full
duplex)
10000M
10/100/100
0M
GE
electrica
l port
2
Auto-negotia
tion 1000
Mbit/s (full
duplex)
1000M
10/100M
⚫
to obtain information about the cables and optical
modules supported by the LOM ports.
⚫
The LOM ports support NC-SI and PXE.
⚫
The LOM ports do not support forced rates.
⚫
The electrical LOM ports cannot be connected to power over Ethernet (PoE)
devices (such as a switch with PoE enabled). Connecting a LOM port to a PoE
device may cause link communication failure or even damage the NIC.
⚫
The electrical LOM ports (GE electrical ports) do not support SR-IOV.
⚫
Forcibly powering off a server will cause intermittent NC-SI disconnection and
disable the WOL function of the LOM ports. To restore the NC-SI connection,
refresh the iBMC WebUI.
Figure 5-31
LOM port
1
GE electrical port (LOM
port 2)
2
GE electrical port (LOM
port 1)
3
10GE optical port (LOM
port 4)
4
10GE optical port (LOM
port 3)