Indicator
Description
Connection status
indicator/Data
transmission status
indicator for a GE
electrical port
● Off: The network port is not connected.
● Yellow and green indicators steady yellow: The
network port is properly connected.
● Yellow and green indicators blinking alternately: Data
is being transmitted.
5.7 I/O Expansion
5.7.1 PCIe Cards
PCIe cards provide ease of expandability and connection.
●
The electrical ports provided by PCIe NICs cannot be connected to power over
Ethernet (PoE) devices (such as a switch with PoE enabled). Connecting such
an electrical port to a PoE device may cause link communication failure or even
damage the NIC.
●
Contact your local sales representative or use the
determine the components to be used.
●
When IB cards are used to build an IB network, ensure that the IPoIB modes of
the IB cards at both ends of the network are the same. For details, contact
technical support.
5.7.2 PCIe Slots
PCIe Slots
Figure 5-26
PCIe slots
FusionServer 2488 V5 Server
Technical White Paper