![xFusion Digital Technologies FusionServer 2488 V5 Manual Download Page 35](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-2488-v5/fusionserver-2488-v5_manual_4673763035.webp)
●
SDDC
●
SDDC+1
●
Rank sparing mode
●
Static virtual lockstep
●
Faulty DIMM isolation
●
Memory thermal throttling
●
Memory address parity protection
●
Memory demand/patrol scrubbing
●
Device tagging
●
Data scrambling
●
Adaptive double device data correction (ADDDC)
●
ADDDC+1
5.5 Storage
5.5.1 Drive Configurations
Table 5-7
Drive Configuration
Configuration
Max. Front Drives
Drive Management
Mode
8 x 2.5" Drive
Configuration (8 x SAS/
SATA)
● Front drive: 8 x 2.5"
– Slots 0 to 7 support
only SAS/SATA
drives.
1 x RAID controller card
● PCIe RAID controller
card: must be installed
in slot 7.
24 x 2.5" (16 x SAS/SATA
+ 8 x NVMe) drive
configuration
● Front drives: 24 x 2.5"
– Slots 0 to 3 and
slots 20 to 23
support only NVMe
drives.
– Slots 4 to 19
support only SAS/
SATA drives.
1 x RAID controller card
+ 2 x NVMe adapters
● PCIe RAID controller
card: must be installed
in slot 8.
● NVMe adapter: must
be installed in slots 7
and 9.
25 x 2.5" Drive
Configuration (25 x SAS/
SATA)
● Front drives: 25 x 2.5"
– Slots 0 to 24
support only SAS/
SATA drives.
1 x RAID controller card
● PCIe RAID controller
card: must be installed
in slot 7.
Note:Contact your local sales representative or use the
determine the components to be used.
FusionServer 2488 V5 Server
Technical White Paper
5 Hardware Description
Issue 06 (2023-12-12)
Copyright © xFusion Digital Technologies Co., Ltd.
28