XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL... User Manual Download Page 13

Pressing the 

5

and

6

buttons will scroll the display through all active fire conditions.  More detailed

information (if applicable) can be viewed by pressing the panel’s more information button.  To
return to the main access level 1 menu press the escape

3

button.

Display Fault Events

This function is only available if there are active faults on the system.  If available, press the
accept

4

button once and a window similar to the one below will appear:-  

Pressing the 

5

and

6

buttons will scroll the display through all active faults. More detailed informa-

tion (if applicable) can be viewed by pressing the panel’s more information button.  To return to the
main access level 1 menu press the escape

3

button.

Display Disablements

This function is only available when there are active disablements on the system.  If available, press
the accept

4

button once and a window similar to the one below will appear:-  

Pressing the 

5

and

6

buttons will scroll the display through all active disablements. More detailed

information (if applicable) can be viewed by pressing the panel’s more information button.  To
return to the main access level 1 menu press the escape

3

button.

Display Zones In Test

This function is only available if there are zones being tested.  If available, press the accept

4

button

once and a window similar to the one below will appear:-  

Pressing the 

5

and

6

buttons will scroll the display through all zones in test mode. More detailed

information (if applicable) can be viewed by pressing the panel’s more information button.  To
return to the main access level 1 menu press the escape

3

button.

Lamp test

This function tests the panel’s lamps (its LED indicators and display) to ensure they are working correctly.  

When selected, press the accept

4

button and all of the panel’s LED indicators will illuminate steady

for approximately two seconds and its display will progressively block fill.  The panel’s internal
sounder (if enabled) will also sound.  Upon completion, the panel will return to the main access
level 1 menu.  If any of the LEDs fail to illuminate or the display does not function correctly, report
the fault(s) to the designated site engineer and make a note of it in the fire system’s log book.

Display Alarm Counter

This function displays the total number of times the panel has been in a fire alarm condition. When
selected, press the accept

4

button once and the display will show the total number of times the

panel has been in a fire condition since it was installed AND the total number of times it has been in
alarm since its alarm counter was last cleared, for example:-

To return to the main access level 1 menu press the escape

3

or accept

4

button.

XFP USER MANUAL & LOG BOOK • Approved Document No. DFU2000501 Rev 2 • Page 13 of  28

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL

Zone 1: Ground Floor

There are faults on this zone

1st Zone: 1: Shop floor

On: This Panel: Is Disabled

Zone 1: North Stairs
Is On Test

LAMP TEST?

Display Alarm Counter

AL1

Total Alarms = 12

Alarms since 01/01/05 = 7

Summary of Contents for NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL...

Page 1: ...XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL user manual and log book approved document no DFU2000501 Rev 2...

Page 2: ...u options 12 Displaying fire fault disablement and test events 12 Testing the panel s lamps its indicators and liquid crystal display 13 Displaying the panel s alarm counter 13 Access level 2 authoris...

Page 3: ...the contents of the panel s separate engineering manual and have the necessary skills for maintaining this equipment If the enclosure is damaged in any way expert advice should be sought regarding its...

Page 4: ...me the system enters day building occupied and night building unoccupied mode and to test the panel s indicators and liquid crystal display to ensure they are working correctly All of these functions...

Page 5: ...system create faults or false alarms 47h 8 Ensure that any structural or occupancy changes planned for the building are done so with due and early consideration given to any changes that may be requir...

Page 6: ...teady red when the alarm is silenced Subsequent fire conditions will restart the General Fire LED flashing until it is silenced again Fire Zones LEDs One or more of these LEDs will flash red in an ala...

Page 7: ...Silences the panel s internal sounder Menu Provides access to the panel s user menus Scroll up down Dependent on the status of the panel these buttons 56 scroll vertically through any fire pre alarm o...

Page 8: ...rtain outputs which may include sounders relays and or output units will not trigger in the event of a fire alarm condition for a set period of time as programmmed by the system engineer Pressing the...

Page 9: ...to fire but all previous zones will now appear on a step by step basis with details of which order they went into fire i e 1st zone 2nd zone etc Pressing the more information button at any time will g...

Page 10: ...alarm is in a zone set up with an investigation delay period Press the more information button to display the actual device that has triggered the 1st stage fire condition pressing more information ag...

Page 11: ...other faults information pertinent to that fault will be displayed instead if available For device specific faults pressing the more information again will display the unique ID code and address locat...

Page 12: ...does not work the code may have been changed by an authorised user engineer A record of any changes should appear on the System Setup Data Chart on page 20 of this user manual If they do not contact...

Page 13: ...s in test mode More detailed information if applicable can be viewed by pressing the panel s more information button To return to the main access level 1 menu press the escape3button Lamp test This fu...

Page 14: ...witch to the armed position Silencing the alarm sounders To silence any active alarm sounders enter access level 2 see above and momentarily press the SILENCE RESOUND SOUNDERS button The alarm sounder...

Page 15: ...4button and the display will show the total number of times the panel has been in a fire condition since it was installed AND the total number of times it has been in alarm since its alarm counter was...

Page 16: ...event history when no printer is connected the following window will appear The DISPLAY EVENT HISTORY menu option when selected displays the panel s 500 event log on the display For example Initially...

Page 17: ...bling the zone itself ENABLE DISABLE SOUNDERS This function allows you to disable one or more sounder groups from sounding in a fire condition When selected press the accept4button and a window simila...

Page 18: ...s the accept4button to select the desired option The window will now move to the next device allowing further enablements or disablements to be made Alternatively to return to the previous menu press...

Page 19: ...ll accept the code and you will be taken back to access level 2 If you type an incorrect confirmation code you will be prompted to start the new code entry sequence again BE SURE TO KEEP A RECORD OF T...

Page 20: ...e panel only is 3 3 3 3 four presses of the6key If this code is changed make a note of the changes here New access level 2 code Date changed __________________ ADDITIONAL INFORMATION We recommend any...

Page 21: ...tor that triggers any of the above fire alarm signals if known I Dates times and type of all faults and defects I Dates and times of all maintenance e g service visit or non routine attention USER SIT...

Page 22: ...ing fire drills actual fire alarms disablements or enablements and faults should be recorded here False alarms and maintenance work should be recorded on page 18 DATE TIME EVENT e g test fire alarm si...

Page 23: ...ev 2 Page 23 of 28 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL 16 CFP USER MANUAL Approved Document No DFU7001000 Rev 4 CFP 2 4 8 ZONE FIRE ALARM PANEL DATE TIME EVENT e g test fire alarm si...

Page 24: ...ev 2 Page 24 of 28 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL 16 CFP USER MANUAL Approved Document No DFU7001000 Rev 4 CFP 2 4 8 ZONE FIRE ALARM PANEL DATE TIME EVENT e g test fire alarm si...

Page 25: ...ev 2 Page 25 of 28 XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM PANEL 16 CFP USER MANUAL Approved Document No DFU7001000 Rev 4 CFP 2 4 8 ZONE FIRE ALARM PANEL DATE TIME EVENT e g test fire alarm si...

Page 26: ...TIME CAUSE IF KNOWN DEVICE THAT TRIGGERED THE ALARM SIGNAL False alarms BRIEF CIRCUMSTANCES WHERE CAUSE IS UNKNOWN RECORD ACTIVITIES IN THE AREA MAINTENANCE VISIT REQUIRED YES OR NO FINDINGS OF MAINTE...

Page 27: ..._______________________ ______________________________________________________________________________________ Variations from the specification and or Section 4 of BS5839 1 2002 see BS5839 1 2002 Cla...

Page 28: ...ification prepared by ________________________________ a copy of which I we have been given J Taking into account the guidance contained in Section 3 of BS 5839 1 2002 I we have not identified any obv...

Reviews: