S
ETUP
OPTION
REFERENCE
77
Font Pitch (char/in)
0.44-99.99 (default is 10.00)
If the default PCL font selected in Font Number represents a fixed pitch
scalable font, determine the width of scalable type. Pitch is measured by
characters per inch, so 10-pitch type fits ten characters per inch.
Font Size (pt)
4.0-999.75 (default is 12.00)
If the default PCL font selected in Font Number represents a
proportionally spaced scalable font, determine the point size (height) of
the font.
Font Source
Internal, Soft Font
Specify the PCL font source to be enabled.
Form Length (lines)
5-128 (default is 60)
Sets the number of lines to be printed per page in PCL jobs.
Offset Mode
On, Off
Specify whether to have jobs offset after they are printed. You must have
a finisher installed.
Paper Size
US, Metric (default is US in the
United States, Metric elsewhere)
Specify the default paper size that the Fiery EXP4110 uses to print PCL
jobs.
Paper Size for System
Pages
US, Metric (default is US in the
United States, Metric elsewhere)
Specify the paper size that PCL system pages print on. System pages are
pages that you print from the Control Panel, such as the PCL Font List.
Print Cover Page
Yes, No
Prints a cover page (job summary) at the end of each print job. If you
select Yes, each print job is followed by a page containing the name of the
user who sent the job, the document name, the server name, the time the
job was printed, the number of pages printed, and the status of the job. If
a PostScript error occurs and the Print to PS Error option is set to Yes,
the cover page lists the PostScript error message instead of the job status.
Print Master
Yes, No
Select Yes to print a FreeForm master when created and printed to the
Fiery EXP4110. The master is retained on the Fiery EXP4110 after
printing unless deleted later. Select No only to process and hold a
FreeForm master on the Fiery EXP4110.
Print to PS Error
Yes, No
Specify whether the Fiery EXP4110 should print the available portion of
a print job when it encounters a PostScript error. Select Yes to print the
portion of the job that was processed before the error occurred; select No
to cancel the print job entirely when a PostScript error is encountered.
Leave this option at No unless you encounter printing problems.
Symbol Set
Desktop, ASCII, Roman_8,
ECMA-94 L1, PC_8...
Choose the PCL symbol set that best matches the needs of users printing
to the Fiery EXP4110.
Text/Graphics Edge
Enhancement
On, Off
Specify whether to minimize the effects of “blasting”, which occurs when
excess amounts of toner on certain media types “blast” beyond the
density boundaries defined in the print job.
Toner Reduction
On, Off
Specify whether to minimize the effects of “blasting”, which occurs when
excess amounts of toner on certain media types “blast” beyond the
density boundaries defined in the print job.
Option
Settings
(default is underlined)
Description