PREINSTALLATION
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE
3-17
Printer
U.S. and Canada,
60Hz:
International, 50 Hz
(WYE):
International, 50 Hz
(DELTA):
120/240 VAC or
120/208 VAC;
50 amp service;
NEMA 14-50R
KVA 7.3 (operating)
380, 400, 415 VAC
(3 phase, 5 wire);
20 amp service (WYE)
220, 230, 240 VAC (3 phase, 4 wire);
30 amp service (DELTA)
Audible noise
Standby:
Operating:
Continuous: 52 dB (A)
Impulse: N/A
Continuous: 67dB (A)
Impulse: 72dB (A)
Optional peripheral cabinet
U.S. and Canada,
60Hz:
International, 50 Hz:
208/240 VAC (1 phase) or
208/220 VAC (Line 1 to line 2);
15 amp service;
NEMA6-15R or
ANSI C73, 20R
KVA .9 in both standby and operating
200/230 VAC (1 phase);
15 amp service
Optional bypass transport
The power requirements for the bypass transport module are all
satisfied by the DocuPrint 96/DocuPrint 96MX LPS printer module.
Agency certification
UL, CSA, CE Mark, EC 950, VDE 0871 (Level AQ) and 0875, EEC
82/499, and CISPR 22 Class A.
Table 3-6.
DocuPrint 96/DocuPrint 96MX Environmental and
electrical requirements (continued)
Environmental requirements
Summary of Contents for DocuPrint 96
Page 4: ...iv XEROX DOCUPRINT 96 DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE...
Page 8: ...TABLE OF CONTENTS viii XEROX DOCUPRINT 96 DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE...
Page 18: ...INTRODUCTION xviii XEROX DOCUPRINT 96 DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE...
Page 62: ...PREINSTALLATION 3 32 XEROX DOCUPRINT 96 DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE...
Page 64: ......
Page 68: ...INSTALLATION 4 4 XEROX DOCUPRINT 96 DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE...
Page 112: ...GLOSSARY GLOSSARY 30 XEROX DOCUPRINT 96 DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE...
Page 116: ...1 1 52 2 835 17 2 835 17 0 36 167 7 21 3 11 1 8...