2 ESC/P Mode Settings
Extension
Sets whether or not to enable the specified extender. Printing can be controlled using text
code when the extender is enabled. Default is [Disable].
Note
• Extended commands are prefixed with the extender, followed by command recognition data and
parameter data, if necessary. An “extender” is the first two bytes (ESC (1BH in Hex) followed by a “;”
(semicolon, 3BH in Hex) of an extended command.
Extended Text
Sets the extender (first two bytes) of an extended command if you want to enable printing
by text codes. Valid codes are 0x21 to 0x7d. Default is [&%].
Note
• Extended commands are prefixed with the extender, followed by command recognition data and
parameter data, if necessary. An “extender” is the first two bytes (ESC (1BH in Hex) followed by a “;”
(semicolon, 3BH in Hex) of an extended command.
Stored Jobs Menu
Settings can be registered to NV memory (No. 01 to 05) and called up as required.
At startup
[At startup] refers to the reading of non-volatile memories (No. 01 to 05) pre-registered by
[Store] when the power is switched on or the system is reset.
Here, set the No. of the NV memory to call up.
The default is [Factory], which means that the default settings are called up when the printer
is started up.
Retrieve
This feature calls up pre-registered settings.
Sets the No. of the memory to call up.
The default is [Factory], which means that the default settings are called up.
Store
There are two types of memory, ROM for storing defaults, and NV memory (No. 01 to 05)
for holding user settings.
With register memory, the various preset mode menu settings are registered as a group to
NV memory (No. 01 to 05).
Registering these settings in advance makes it easier to call up mode menu settings, and
you are no longer required to repeat the same settings each time after the printer is switched
on.
Registered settings are stored until you initialize NV memory or clear memory.
Delete
Clears the settings registered to NV memory.
Sets the No. of the memory to clear.
Note
• [No. 01] to [No. 05] are not displayed if there is nothing registered in memory.
• To protect against the wrong settings being made due to commands received from a client, we
recommend that you press the <Online> button and go offline while you are registering data to memory.