XEROX DFC165 & DWC165c Service Manual
7.2.10 Removing the CCD Board
This board must be replaced at the laboratory only!
1) Remove the scanner unit (see section 7.2.9)
2) Remove the two screws and move the CCD board away from the scanning unit.
Then unplug the CCD flat cable, the sensor flat cable and the LED array wire (see
fig. 7-32), and then remove the CCD board
Fig. 7-32
Warning:
having replaced the board, make the CCD adjustment (see section 6.3).
7.2.11 Removing the LED Array
1) Remove the scanner unit (see section 7.2.9)
2) Release the left bushing on the document ejector roller, by turning it towards the
front and slide the roller out from the right-hand side (see fig. 7-33)
Fig. 7-33
screws
LED array wire
CCD flat
cable
sensor flat
cable
bushing
document
ejector roller