Xeos Technologies Inc. Alert Geomatics Xi-100b User Manual Download Page 26

 
 

Xi-100b User Manual Version 4.1 

 

A-05-018-3: Xi-100b Port 1 – Power Supply 

Summary of Contents for Alert Geomatics Xi-100b

Page 1: ...Xi 100b User Manual GLOBAL SATELLITE TRANSCEIVER Version 4 1 April 2019...

Page 2: ...2011 Original Document 2 0 Aug 2014 Updated format and technical specification 2 1 Feb 2015 Update to connection and command information 3 0 May 2014 Format Revision RUDICS information 3 2 Nov 2017 D...

Page 3: ...g Email Command Files 6 Sending Commands Using XeosOnline 7 Setting up to Send 7 Hardware 8 Front Panel 8 SIM Card 9 Testing the Xi 100b before Deployment 9 Internal Test Protocol 9 Commands 11 Settin...

Page 4: ...ps 17 RUDICS Tunnel Setup 18 Setup Specifics Main setup 18 Setup Specifics Individual Tunnels 18 Making the connection 19 Appendix A Programming the Xi 100b 21 Required Equipment 21 Setup 21 Appendix...

Page 5: ...0b were low power and reliable operation while in the harsh Antarctic environment The Xi 100b implements remote programmability and heating capabilities within a rugged casing capable of withstanding...

Page 6: ...a human readable format RUDICS If the best choice is to use a RUDICS tunnel please contact Xeos for assistance in setting up and managing a RUDICS tunnel if you do not already have one established It...

Page 7: ...email addresses for commands and responses Sending Commands Using XeosOnline Before using XeosOnline make sure that your account has been set up and your device added to your organization Contact acti...

Page 8: ...Satellite Antenna TNC Connection for an external Iridium Antenna 4 DAS OK LED Indicates whether the DAS test has passed or failed 5 SAT OK LED Indicates whether the SAT test has passed or failed 6 Mdm...

Page 9: ...m for satellite communication If the Mdm OK LED stops blinking and then goes out there is a problem with either the modem or the connection between the modem and the main circuit board Contact Xeos Te...

Page 10: ...Flashes Success Solid Failure Nothing External Sensor Automatically after power up Powers the internal interface and attempts to connect to the external device During Flashes Success Solid Failure Not...

Page 11: ...ead temperature Enable enable X Y Enable Disable a system X system q uanterra s ensors r udics or h eater Y Enable 1 or disable 0 enable with no follow up information returns the current state of the...

Page 12: ...ress should be set to be on the same subnet as the peripheral device Mask enmask Set the Xi 100b s Net Mask DefRtr DefRtr Shows the Xi 100b s Router IP address it should be set identically to the Gate...

Page 13: ...D messaging and sets the timer for 1 hour Timer Description SBD Iridium message timer ESP Start up period timer when elapsed the Xi 100b will turn off diagnostics and LEDs QQV Quanterra quickview time...

Page 14: ...24 hours Number of messages received by the Xi 100b in the last day QQVMap Q330 Quickview channel map bitmap hex RTMax RUDICS temperature Max RVMin RUDICS Voltage minimum SBD Iridium timer shows Enabl...

Page 15: ...evice must be listening on the specified port in order for a connection to be initiated 3 The IP and Port of the XeosOnline server through which you will connect to the Iridium gateway This will be su...

Page 16: ...up to work with the Quanterra Q330 seismic system by default To connect to an alternative device several settings must be changed before deployment RUDICS settings 1 For devices using Ethernet to conn...

Page 17: ...erfacing with the Peripheral Device Connection between the Xi 100b and a peripheral device is dependent upon several items Most of these involve the IP setups of both devices incorrect settings will c...

Page 18: ...ugh another Iridium provider Connect Script Allow script to be used to download data Alternate Script Filename Script for downloading data IMEI Device to which the tunnel is associated Setup Specifics...

Page 19: ...DICS start attempt That means that each RUDICS start command block must include the RUDICS mode desired and the turn on command For example a RUDICS Single Mode on block would contain rdcsmode 1 rdcs...

Page 20: ...service 110web To reach this destination one would enter the following on a browser online xeostech com 21101 Alternatively to connect to the device called 110telnet enter the following online xeoste...

Page 21: ...ower Source 12V Setup 1 Connect the Xi 100b to a power supply but do not turn on power 2 Plug in the programming cable to your PC and connect it to the Xi 100b 3 Make sure the Serial to USB adapter dr...

Page 22: ...Speed select 19200bps 8 Apply 12VDC to the power leads of the Xi 100b The firmware will begin to load in the Messages window 9 When the Firmware has finished upgrading the Messages window will displa...

Page 23: ...ectrical Input Voltage 8 5 20VDC Sleep Autonomous Mode 450 uA Iridium SBD Session 150 mA 15s avg RUDICS connection 350 mA no heaters 700 mA heaters Communications Iridium Modem 9522B Iridium Transceiv...

Page 24: ...WR EXT Sensor 12 Pin size 14 A RS 232 TXD 0 B RS 232 RXD 0 C GND D RS 232 RTS 0 E RS 232 CTS 0 F RS 232 DTR 0 G RS 232 DSR 0 H SNS PWR J SUPPLY 8 5 20VDC K SUPPLY GND L SNS GND M PGP Pinout DAS Interf...

Page 25: ...A 05 018 1 Xi 100b Port 1 Power Supply External Sensor DB9...

Page 26: ...Xi 100b User Manual Version 4 1 2 A 05 018 3 Xi 100b Port 1 Power Supply...

Page 27: ...Xi 100b User Manual Version 4 1 3 A 05 019 1 Xi 100b Port 2 Ethernet RJ45 Serial DB9...

Page 28: ...Xi 100b User Manual Version 4 1 4 A 05 019 2 Xi 100b Port 2 Q330 Serial QNet...

Page 29: ...Xi 100b User Manual Version 4 1 5 A 05 019 4 Xi 100b Port 2 Q330 Serial Ethernet RJ45...

Page 30: ...Xi 100b User Manual Version 4 1 6 A 05 019 5 Xi 100b Port 2 Q330 Serial...

Page 31: ...Xi 100b User Manual Version 4 1 7 A 05 027 Xi 100b Port 2 Xi 100b Programming Cable DB9...

Page 32: ...Xi 100b User Manual Version 4 1 8 A 05 028 Xi 100b Port 2 Q330 QNet...

Page 33: ...f failure of the product has resulted from accident abuse or misapplication Any replacement product will be warranted for the remainder of the original warranty period or ninety 90 days whichever is l...

Reviews: