Set
options
Click
Operation
Option
from the Option menu to open the Operation Option
screen. Set each of the following options:
o
Insertion
Test
indicates whether to check the pin contact.
o
Device
ID
Check
indicates whether to check the ID of the device.
o
Beeper
indicates whether the beeper alarms a sound when the
operation succeeds/fails.
o
Auto
Increment
Function
indicates an automatic increase in the label
number written to each chip.
o
Address
Change
indicates whether a different start and end address
shall be applied for the programming zone of the device.
To set the order of the batch processing functions, select
Edit
Auto
from the
Options menu. The system displays the Edit Auto screen.
For devices that include the configuration word, you must set the
configuration word before programming to ensure that the chip can be used on
the target system. The configuration words for some devices are contained in the
data file. Therefore, the system automatically loads the configuration word into
the configuration word buffer when loading the data file. For some devices, you
must manually make the selection. Select
Device
Configuration
Word
from
the Device menu to open the ConfigWord screen.
Many devices must meet some special requirements for the programming of a
chip, including special algorithms conventions. Read the device manual or
instructions carefully and adjust the operation steps or buffer data as needed.
3.2.5
Execute
programming
Connect the signals with cables according to the device info of IS416 at first. The
operation procedure for the programming of a chip is described as the following steps:
Blank Check
NOTE
: You can skip this step if the chip is brand new.