4.4 Connecting the MM-202BX to the ISP Backbone
Note
: To connect multiple MM-202BX units and the EU-200BX EMS unit, it is recommended to
prepare a Switch Hub in advance for installation.
①
Check the connection between the backbone and Switch Hub.
②
Connect the UPLINK port of the MM-202BX to the Switch Hub using the RJ-45 cable.
Figure 6 Connecting the MM-202BX to the ISP backbone
③
Once the MM-202BX is connected to the backbone, turn on the power of the MM-
202BX.
④
Wait approximately 3 minutes for the EU-200BX to finish the remote registration
process.
4.5 Checking the Final Connections
Note
: When using the SU-200BX test unit, make sure it is set to Factory Default mode.
4
4.5.1 Checking the Ethernet connection
①
Connect the laptop PC to the LAN port of the MM-202BX using a RJ-45 cable.
②
Configure the network properties of the laptop PC as provided by the ISP.
③
Confirm if the Internet connection is working properly.
4.5.2 Checking the PLC connection using the SU-200BX test unit
①
Turn off the power of the MM-202BX.
②
Disconnect ALL cables (including the RJ-11 cable) from the MM-202BX except for the
4
Please refer to the SU-200BX Installation Guide for details on resetting to Factory Default
mode.
The ACT LED of the SU-200BX will blink when successfully changed to the factory
default mode.