Copyright | C6AM User Manual, Version 1.2.2
26
Figure 4.6.3
In case that the station will be connected with a LAN cable for the backend connection,
this cable should be laid through waterproof gland on the bottom to the RJ45 Port on
the A8 communication board, shown in Figure 4.6.4. (it’s suggested to use such soft flat
LAN cable like in figure because of the limited place for installation. Any other RJ45
converter in the charger could be installed by customer if needed)
In case that the station connects with backend through SIM card, the SIM card slot
shown in Figure 4.6.4 can be used. (only for standard SIM card size 15x25mm)
RJ45
SIM card slot
Figure 4.6.4
After installing the cable into the charging station, the bottom of the charging station is
fixed to the concrete platform by 4 fixed concrete anchor screws M10.
4.7 Verification of Measurement Values
Please ensure all measured values are within specified range before proceeding to