Configure Other Protection Mechanisms
M370046-01
5-71
5
Protection Mask (Enable Alarms)
The protection mask allows for the different alarms to be masked,
completely disabling them. This means that the SCPI status and
operations registers will not detect the alarms. You will have no way of
knowing the current operation state of the alarm. The protection mask is a
feature that is only accessible using the SCPI command noted below.
Command:
[:]SYSTem[<channel>]:PROTection[:MASK] {?|<mask>}
Where
<mask> is the bit mask for disabling the alarms. See Table 5-19 for
details.
See “Alarms and Errors” on page 3–18.
Table 5-19
Alarms Bit Mask
Bit
Bit Weight
Bit Name
Description
0
1
AC Fail
Not used. Always 1.
1
2
OTP
Over Temperature protection.
2
4
N/A
Not used.
3
8
Fan Stop
Fan on the main board.
4
16
N/A
Not used.
5
32
Interlock
Not used. Always 1.
6
64
OVP
Not used. Always 1.
7
128
OCP
Not used. Always 1.
8
256
Foldback
Foldback protection.
9
512
Shutdown
External Shutdown pin
10
1024
UVP
Under Voltage protection.
All manuals and user guides at all-guides.com
Summary of Contents for XTR 33-25
Page 2: ...All manuals and user guides at all guides com...
Page 6: ...All manuals and user guides at all guides com a l l g u i d e s c o m...
Page 18: ...xvi All manuals and user guides at all guides com...
Page 30: ...1 8 All manuals and user guides at all guides com...
Page 92: ...3 48 All manuals and user guides at all guides com...
Page 198: ...5 72 All manuals and user guides at all guides com...
Page 262: ...A 36 All manuals and user guides at all guides com...
Page 284: ...IX 4 All manuals and user guides at all guides com...
Page 285: ...All manuals and user guides at all guides com...