4-30
Query for ISOL Voltage Input Level
To query for ISOL voltage input level from non-isolated input:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
UAPr
is displayed on the output voltage display.
2. If the mode is currently
nonE
then select any other ISOL mode. If
this step is done, be sure to restore the ISOL setting to
nonE
when
the operation is complete. Otherwise, do not rotate the Rotary knob/
Enter button to keep the current ISOL mode.
3. Press the rotary knob/Enter button to select the ISOL mode.
The output voltage display should read
LE U
and the output current
display will display ISOL level.
4. Press the rotary knob/Enter button to return to normal mode.
5. If the ISOL mode was modified in step 2, execute the procedure to
deactivate the ISOL voltage mode.
Quick Tip
Remote operation
uses these SCPI
commands. See
page 5–1.
The SCPI command for these instructions are:
[:]SYSTem[<channel>]:REMote:SOURce[:VOLTage] <?|LOCal
|AVOLtage|IAVoltage|ARESistive|IAResistive>
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel
[:VOLTage][:ISOlated]
[:]MEASure[<channel>][:SCALar]:APRogram[:VOLTage]
:ISOlated[:DC]?
All manuals and user guides at all-guides.com
Summary of Contents for XTR 33-25
Page 2: ...All manuals and user guides at all guides com...
Page 6: ...All manuals and user guides at all guides com a l l g u i d e s c o m...
Page 18: ...xvi All manuals and user guides at all guides com...
Page 30: ...1 8 All manuals and user guides at all guides com...
Page 92: ...3 48 All manuals and user guides at all guides com...
Page 198: ...5 72 All manuals and user guides at all guides com...
Page 262: ...A 36 All manuals and user guides at all guides com...
Page 284: ...IX 4 All manuals and user guides at all guides com...
Page 285: ...All manuals and user guides at all guides com...