Hardware and Connection Setup
M370046-01
5-7
5
Configuring Remote Control Using RS-485
RS-485 Communication Cable with RJ-45 to DB-9
Communication control cable with DB-9 pinout (female) on the PC side
(see Figure 5-2) and RJ-45 shielded connector on the power supply.
The cable length should be 9.84 feet (3 m) or longer.
Table 5-5
DB-9 Pinouts
Pin
Name
Description
1
GND
Ground
2, 3
NC
No connection
4
RXD+
Receive data
Twisted
pair
5
RXD–
Receive data
6, 7
NC
No connection
8
TXD+
Transmit data
Twisted
pair
9
TXD–
Transmit data
Table 5-6
RJ-45 Plug Pinouts
Pin
Name
Description
1, 2
NC
No connection
3
TXD+
Transmit data
Twisted
pair
4
TXD–
Transmit data
5
RXD+
Receive data
Twisted
pair
6
RXD–
Receive data
7
GND
Ground
8
NC
No connection
Figure 5-5
RS-485 Communication Cable with DB-9
DB-9 connector on PC
RJ-45 plug
All manuals and user guides at all-guides.com
Summary of Contents for XTR 33-25
Page 2: ...All manuals and user guides at all guides com...
Page 6: ...All manuals and user guides at all guides com a l l g u i d e s c o m...
Page 18: ...xvi All manuals and user guides at all guides com...
Page 30: ...1 8 All manuals and user guides at all guides com...
Page 92: ...3 48 All manuals and user guides at all guides com...
Page 198: ...5 72 All manuals and user guides at all guides com...
Page 262: ...A 36 All manuals and user guides at all guides com...
Page 284: ...IX 4 All manuals and user guides at all guides com...
Page 285: ...All manuals and user guides at all guides com...