Installation
Location, Mounting, and Ventilation
Revision A
35
Location, Mounting, and Ventilation
Rack
Mounting
The rack mount kit allows you to mount two units side by side in a standard 19in.
(483 mm) rack space.
1. Install commercially available rack slides, if used. Follow the manufacturer’s
instructions.
2. Remove the four (4) rubber feet from the bottom of each power supply.
3. Place the power supply (or supplies) into the rack mount pan (option
RM3-XHR).
4. Screw four (4) #6-32 x ¼in. flat head, rack mounting screws through the pan into
the threaded holes on the bottom of each power supply.
5. Install the rack mount pan in the rack.
Ventilation
Always ensure that cooling air reaches the ventilation inlet on the lower front of the
unit and that the fan can exhaust from the rear of the unit. Additional ventilation
space at the top and bottom of the supply will further lower internal operating
temperatures.
Check
“Environmental Specifications”
for the specified operating ambient
temperature range for the power supply.
!
CAUTION
Ensure that any rack mounting screws do not extend more than 1/4in. (6.3 mm)
into the base of the unit.
TM-XROP-01XN.book Page 35 Monday, March 22, 2004 4:10 PM
Summary of Contents for XHR 100-10
Page 2: ......
Page 3: ...Operating Manual for XHR Series Programmable DC Power Supply...
Page 14: ...List of Figures xii Operating Manual for XHR Series Power Supply...
Page 16: ...List of Tables xiv Operating Manual for XHR Series Power Supply...
Page 49: ...Installation Load Connection Revision A 47 Figure 2 9 Multiple Loads with Remote Sensing...
Page 85: ......