Configuration
4–10
445-0089-01-01
Auto Restart After
Error
If you select
Yes
, the PROsine will attempt to restart (five attempts) after a fault
has occurred.
If you select
No
, the PROsine ceases operation when an error occurs. It then
requires that you manually restart the unit by going to the
Configuration
menu
and clearing the error.
Exception:
If the PROsine shuts down in Invert mode because of low battery and
the charger is enabled and AC is then supplied to the PROsine, it will
automatically charge the battery.
Reset to Defaults
You can only apply
Load Factory
,
Save as Custom
, or
Load
Custom
if both the
charger and the inverter are disabled. The display panel should respond with
OK
.
If
Error
appears, disable invert and charge and try again.
Load Factory
If you select
Load Factory
, all PROsine settings will be reset to their default
values.
Save Custom
If you want to change the settings temporarily, you may want to save your current
system settings. To save the current configuration of the PROsine, select
Save
Custom
. You can then restore this configuration to the PROsine at a later time.
Load Custom
Select
Load Custom
to restore your custom settings to overwrite the current
PROsine settings.
WARNING: Shock hazard
If
Auto Restart
is selected, AC voltage can reappear at the loads without notice after a
fault has occurred and cleared.
Summary of Contents for PROsine 2.0
Page 1: ...PROsine 2 0 Inverter Charger User s Manual...
Page 2: ......
Page 3: ...PROsine 2 0 Inverter Charger User s Manual...
Page 8: ...vi...
Page 12: ...x...
Page 18: ...xvi...
Page 20: ...xviii...
Page 68: ...Installation 3 26 445 0089 01 01...
Page 120: ...Series Operation 7 12 445 0089 01 01...
Page 128: ...A 8...
Page 132: ...B 4...
Page 147: ......