Installation
3–10
975-0289-01-01
Permanent Wiring (Hardwiring)
Terminal Access
WARNING: Shock Hazard
Hardwiring this equipment should be done by a person with adequate knowledge
of electrical and building code requirements. Failure to follow safe installation
practices could result in a significant, and possibly lethal, shock hazard.
Figure 3-9
Terminal Access for Hardwiring
Remove the 5 #6-32
Phillips screws on
the top of the
inverter. Lift off the
panel to expose the
terminals.
Wiring Terminals Enlargement
BEFORE REMOVING INVERTER COVER:
Check to ensure the AC Indicator LED is NOT
illuminated and that there are absolutely no
sources of power connected to the PowerHub.
AC Indicator LED
Once hardwiring is complete 120 Vac power will be
available at the outlets on the front panel as well as the
outlets directly connected to the PowerHub through the
AC Distribution Panel.
975-0289-01-01(PowerHub_1800).book Page 10 Friday, January 5, 2007 12:47 PM